Siemens PUMA V400/M Operation Manual page 123

Vertical turning center
Table of Contents

Advertisement

the tool at tool enable set screen.
▶ Brake Reaction: When tool detects a certain value of off-range, occur alarm screen.
(User select, Retract and stop)
Stop : If tool broken, display tool broken status screen. And machine stop
➁ Default value, ➂ If press this soft key, set default value
➃ Recommend value, ➄ All factor change to automatic mode
➅, ⑧ Assign G-code : User define G-code for not detect current .(TLM Tool setting detail 3,
OEM section)
➆ Delete All Data : Delete all TLM data(about 1min)
(8) Tool Broken Screen
If TLM detects a certain value of off-range, it will generate Cycle alarm.
If TLM detects a certain value of off-range, it will generate Cycle alarm screen
automatically. And then If press RESET (on MCP button), the alarm screen disappears.
① Tool Broken position(W.C.S)
➁ Reaction : If this screen display, user can be selected to next situation. (Change to
Sister Tool, Stop, Continue)
Continue
continue cutting
Retract + Stop
Continue with ST
➂ Violation Value : Broken axis, detected current[A]
machine stop
tool change to replacement tool
PROGRAMMING | 115

Advertisement

Table of Contents
loading

Table of Contents