EQ33-2 SETUP menu
Time/distance scale - will indicate the elapsed time or distance for
the echo picture. The readout will appear in the upper part of the
echo display. Toggle between time and distance in "Scroll synchro-
nisation", section 5.6.
Restart of AUTO pulse/power - will automatically restart the
echosounder if bottom detection has been lost for the chosen time
interval i.e. 10, 20 or 40 seconds. The AUTO pulse and power will
restart from 10W and SHORT pulse.
Echo sampling - is preset to BOTTOM, which enables auto range
and a view all the way to the bottom. For vessels moving at high
speed with the risc of losing bottom detection, RANGE or a max.
depth setting (50 to 2000m) is recommended. The unit will not wait
for a bottom echo, but transmit a new pulse as soon as the selected
range has been reached. Auto range is automatically switched off.
The depth alarm setting will have a higher priority than the selected
depth range.
Demo mode - the echosounder will function as though a transducer
was connected, but all data presented in the display will be simulated.
8.2 Pilot / Position setup
MENU
Call up the menu bar, and...
load Pilot/Position setup display
6,1
Pilot/Pos setup:
Display position as:
Display speed as:
Course and bearing as:
Time:
MENU
Go to the function you wish to change
13:43:56
Exit
LAT/LON
MAGNETIC
Date:
15-01-2006
Accept
Chapter 8-3
STW
ENT