Microcomputer-controlled sealer for sterilizable bags, medical pouch sealer (26 pages)
Summary of Contents for Van Der Stahl OPL Series
Page 1
Printed JAN 2017 2nd Edition 2.02E MICROCOMPUTER CONTROLLED TEMPERATURE CONTROL I MP ULSE SEA LE R OPL SERIES DOUBLE-SIDE HEATING TYPE MANUAL www.vanderstahl.com...
Page 2
Keep this manual on hand when operating the sealer. As a result of research to further improve the OPL series, some details in this manual may differ from your actual machine. For operating problems or product information, please contact...
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E Table of Contents Replacing the routine maintenance parts ………………………………………………………………… 4 Preparation for parts replacement …………………………………………………………………………………………………… 4 How to shift fluoro glass sheet ……………………………………………………………………………………………………… 5 Heating element replacement ……………………………………………………………………………………………………… 6 Glass tape and Sarcon sheet replacement ………………………………………………………………………………………… 8 Silicone rubber replacement …………………………………………………………………………………………………………...
Follow the directions on this manual when replacing parts. Replacing parts in the way ignoring this Warning manual could cause malfunction of the machine as well as electrocution and fire. Always use only specified parts sold through Van der Stahl Scientific. Unspecified parts may cause Warning malfunction of the machine.
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E 2 How to shift fluoro glass sheet Essential tools: Scissors, a Philips screwdriver Replace when: The fluoro glass sheet burns, or when the seal becomes messy. Fluoro glass sheet is either sold individually or included in the maintenance parts kit.
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E Upper fluoro glass sheet (For OPL-450, OPL-600 double-side heating type) Loosen two white plastic nuts on the backside (c) Fluoro glass sheet Pressure lever fastening plate of pressure lever so (a) fluoro glass sheet roll bar can be moved.
Page 7
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E Lower heating element replacement (for all models) Remove the fluoro glass sheet. (Refer to “2 How to shift fluoro glass sheet.” Fluoro glass sheet Loosen the screw A of both electrodes with a Heating element Philips screwdriver, and remove the terminal covers.
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E Without loosening the screw B, the Caution heating element will be kept stretched tight. Thus the heating element terminal cannot be inserted between the electrode plate and plate spring. Electrode plate spring Insert a Philips screwdriver into the hole of the electrode cover and loosen screw C.
OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E Cut the new Sarcon sheet 2mm longer than the seal area for left and right sides and adhere it to the lever. Adhere the glass tape over the Sarcon sheet so it covers the electrode about 5mm.
Page 10
Represented by 1652 Plum Lane, Redlands, CA 92374 800-550-3854 Y6082E JAN 2017 2nd Edition www.vanderstahl.com OPL Double-Side Heating Type Maintenance Manual Ver. 2.02E...