Van Der Stahl FAS-402-CH Series Operating Instructions Manual

Microcomputer controlled tabletop nozzle type c type vacuum sealer
Table of Contents

Advertisement

Quick Links

MICROCOMPUTER CONTROLLED TABLETOP NOZZLE TYPE
V ACU UM SEA LER
FAS-402-CH SERIES
FAS-602-CH
OPERATING INSTRUCTIONS
www.vanderstahl.com
Printed April 2016
1st Edition 1.05E
C TYPE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FAS-402-CH Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Van Der Stahl FAS-402-CH Series

  • Page 1 Printed April 2016 1st Edition 1.05E MICROCOMPUTER CONTROLLED TABLETOP NOZZLE TYPE V ACU UM SEA LER FAS-402-CH SERIES FAS-602-CH OPERATING INSTRUCTIONS C TYPE www.vanderstahl.com...
  • Page 2 FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Thank you for purchasing the FAS-402/ 602-CH series sealer! FAS-402-CH, FAS-602-CH series is a table-top vacuum sealer controlled by the microcomputer, which makes it possible to set up the various operation patterns that the customers require. This manual explains the terms that is used when setting the seal conditions. Please read this manual thoroughly before use for the better understanding on how to set up/operate the FAS-402-CH/FAS-602-CH series.
  • Page 3 As a result of research to further improve the FAS-402/602-CH series, some details in the operating instructions may differ from your actual machine. For operating problems or product information, please contact Van der Stahl Scientific. About the warning labels This manual is designed to...
  • Page 4: Table Of Contents

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Table of Contents Package contents ………………………………………………………………………………………… 6 Warning-caution label location and content ………………………………………………………… 7 Operating precautions …………………………………………………………………………………… 9 For safety operating …………………………………………………………………………………………………………………………… 9 For smooth operation ……………………………………………………………………………………………………………………… 11 Other safeguards …………………………………………………………………………………………………………………………… 12 Outline of structure ……………………………………………………………………………………… 13 Proper operating boundaries for the FAS-402/ 602-CH series ………………………………… 13 Major parts and function ………………………………………………………………………………...
  • Page 5 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Replacing the routine maintenance parts ………………………………………………………… 42 Slide a lower fluoro glass sheet …………………………………………………………………………………………………… 43 Replace a fluoro glass sheet …………………………………………………………………………………………………………… 43 Replace center-dry tape (For double-side heating models) …………………………………………………………………… 44 Replace a heating element ………………………………………………………………………………………………………… 45 Replace glass tape (19mm: pressure lever/ 25mm: seal receiving plate) and Sarcon sheet ……………………………… 46 Replace a silicone rubber (For single-side heating models) …………………………………………………………………...
  • Page 6: Package Contents

    Certificate of inspection, Vacuum pump instruction manual ---- one each. If the items in package are not same with above list, please contact Van der Stahl Scientific. Before using , to verify that the circuit breaker is in the "OFF" position.
  • Page 7: Warning-Caution Label Location And Content

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Warning-caution label location and content Warning - Caution labels are placed in locations where there is a danger of injury to a person or damage to the machine. Label location details are illustrated below. Please check them before beginning operation. Labels not readily apparent are indicated by dotted lines.
  • Page 8 FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Warning-Caution label location and content (Cont’d) CAUTION CAUTION NOZZLE Pay attention to the When the air cock is opened, the seal nozzle moving forward part opens automatically. Do not or backward during vacuum. Pinching may approach to avoid the danger. occur.
  • Page 9: Operating Precautions

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Operating precautions For safety operating In an emergency, unplug the power cord Warning immediately This sealer incorporates a number of safety devices and is carefully designed to prevent fires or other malfunctions. However, should all of the safety devices fail simultaneously, there is a possibility of the fluoro glass sheet catching fire due to a failure of the heating circuit's tripping mechanism that results in the heating element overheating.
  • Page 10 FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Do not use parts other than those specified Warning When replacing parts, always use only specified parts sold through Van der Stahl Scientific. We are not responsible for malfunctions caused by the use of unspecified parts. If the circuit breaker automatically turns to the OFF Warning position If the circuit breaker will automatically turn to the OFF position, there...
  • Page 11: For Smooth Operation

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Use machine properly Caution Read the operating instructions carefully and operate sealer correctly. Accidents or damage caused by misuse of the machine not in accordance with the operating instructions are the sole responsibility of the customer. Printer outlet Caution The printer outlet is located on the top of the machine frame cover.
  • Page 12: Other Safeguards

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E If there is a malfunction in the temperature sensor The temperature sensor is designed to monitor and control heating temperature by directly measuring the temperature of heating element. Therefore, when the sensor tip is not positioned correctly or the sensor is disconnected, the machine will show the error message "Poor heating"...
  • Page 13: Outline Of Structure

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Outline of structure This sealer is an impulse sealer with sponges located on the sealing section to secure the nozzle prior to air Place a pouch Sealing section removal. The air supplied by air pump drives the valve, Sponges cylinder, and nozzle to complete the sealing.
  • Page 14: Major Parts And Function

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Major parts and function Regulator Circuit breaker (with overheat proof circuit) Refer to "7 Proper use of the sealer" The circuit breaker automatically switches off for the detail. when the overheating or short-circuit occurs. Circuit breaker is located behind the dry filter. For the detailed location, refer to “10-2 Appearance dimensions drawing.”...
  • Page 15: Proper Use Of The Sealer

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Proper use of the sealer Secure the work place For safety and efficient operation, please set the sealer in the appropriate place as described below. Installing the machine on an unstable or Warning inclined surface may cause the overturn of the sealer.
  • Page 16: Adjust The Nozzle Height

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Adjust the nozzle height Hollow set screw The nozzle height that comes out from the seal area can (silver) be finely adjusted to the optimum level for each operation. Lift up the frame cover. Turn the hollow set screw on the top of the nozzle supporter with the 2.5mm hexagonal wrench.
  • Page 17: Plugging In The Electrical Power Code

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Plugging in the electrical power code Be sure to connect the power plug directly into the wall outlet with adequate current carrying capacity as described at “10 Specification.” Insert the electric 110V specification power plug fully into the wall outlet. The power consumption varies depending Warning on each model.
  • Page 18: Test Sealing

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Test sealing After setting all the conditions at the control unit, hold the bag by both hands and stretch it tight. Set the bag between seal levers. (Insert the vacuum nozzle into the bag if necessary.) Depress the foot switch to proceed the operation.
  • Page 19: Control Unit Setting And Operation Procedures

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Control unit setting and operation procedures This chapter is composed with the following sections: Operate the machine with the pre-installed operation patterns This chapter explains how to operate the FAS-402-CH, FAS-602-CH series with the pre-installed operation patterns to give you the general idea of how to operate the machine properly. Please get used to the FAS- 402-CH, FAS-602-CH operation with the pre-installed operation patterns.
  • Page 20: Operate The Machine With A Pre-Installed Operation Pattern

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Operate the machine with a pre-installed operation pattern Two operation patterns are pre-installed to the FAS-402-CH, FAS-602-CH series at the time of factory shipment. The sealing parameters of the pre-installed operation patterns (heating temperature etc.) can be Attention changed depending on the customer application. Please refer to “8-4 Reference for control unit setting and machine preparation”...
  • Page 21: Sample Operating Procedures : "Seal Only" Operation

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 8-1-1 Sample operating procedures : “seal only” operation Operation No.[01] SEALING ONLY The seal parameters set at the time of factory shipment: HT : 140ºC/280ºF, CT : 100ºC/200ºF = Refer to “8-5 Operation procedures >>> 8-5-1 Seal only.” The following operation procedures are for Depress the foot switch (2nd) TIPS the brand new machine without any change...
  • Page 22: Sample Operating Procedures : "Manual Vacuum + Sealing" Operation

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-1-2 Sample operating procedures : “manual vacuum + sealing” operation Operation No.[02] VAC & SEAL The seal parameters set at the time of factory shipment: HT : 140ºC/280ºF, CT : 100ºC/200ºF = Refer to “8-5 Operation procedures >>> 8-5-2 Manual vacuuming and sealing.” The following operation procedures are for Place a pouch to the sealing area TIPS...
  • Page 23 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E ・ Pressure lever descends completely down to the seal position and sealing starts. (Heating lamp turns on.) ・ After the heating is finished (Heating lamp turns off), cooling lamp turns on. ・ Cooling is finished. (Cooling lamp turns off.) ・...
  • Page 24: Register Sample Operation Patterns

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Register sample operation patterns   Maximum 10 operation patterns can be stored in the microcomputer controller (control unit). Attention If you are going to register over 10 operation patterns, the message "Entry No' is full Please delete an unnecessary entry No' " is displayed on the digital display. You cannot input a new operation pattern until at least one of the stored operation patterns is deleted.
  • Page 25: Sample Case: How To Register The "Seal Only" Operation

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 8-2-1 Sample case: how to register the “seal only” operation The following operation procedures are for the brand new machine without any change on the TIPS setting. Let’s register "Sealing only" operation to the operation number [05]. Operation setting : Heating temperature 140ºC/280ºF/ Heating time 0.3 seconds/ Cooling temperature 100ºC/200ºF Turn ON the circuit breaker Push...
  • Page 26: Sample Case: How To Register The "Vacuum (Timer) + Seal" Operation

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-2-2 Sample case: how to register the “vacuum (timer) + seal” operation The following operation procedures are for the brand new machine without any change on the TIPS setting. Let’s register "Vacuum timer" operation to the operation number [06]. Operation setting : Heating temperature 140ºC/280ºF, Heating time 0.3 seconds, Cooling temperature 100ºC/200ºF Vacuum time 12 sec.
  • Page 27: Explanation Of The Terms

    Ultrasonic sealer, High-frequency sealer Van der Stahl Scientific's products are mainly the impulse sealer in the above categories. An impulse sealer heat-seals objects by sending high current on impulse to a heater ribbon, equipped on the surface of the heat-sealing blade, to generate heat that enables thermal-sealing through thermal conductivity.
  • Page 28: How To Set The Control Unit

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E How to set the control unit Explanation of each button on the control panel MENU button = Push to display the menu mode 1 Entry 2 Change 3 Delete 4 Maintain ENT button = Push to complete the setting UP/DOWN arrow buttons = Push to move to the setting display = Push to increase or decrease the setting...
  • Page 29: Seal Counter

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E NOTES: The following explains on condition circuit breaker and the power switch are ON. The numeric values on the control unit display is described as “xx”. The cursor position is described as . “ ” mark on the control unit display indicates the different contents by each operation number. The below menu display will be shown.
  • Page 30: Select / Enter / Change The Sealing Method

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-4-4 Select / Enter / Change the sealing 8-4-5 Set the heating temperature method Change the temperature of currently displayed operation pattern: Push button when the display shows one of the registered operation pattern as Push the button when an operation pattern is displayed on the screen.
  • Page 31: Set The Heating Time

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 8-4-6 Set the heating time Without the heating time: Change the temperature of currently Set heating displayed operation pattern: temperature Cool cycle Push the button when an operation pattern Heat cycle Set cooling temperature is displayed on the screen. The following will be displayed.
  • Page 32: Select The Vacuum Pattern

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E If you hold the button in, the numeric value will Press the button. The below display will increase/decrease continuously. Use this method be shown on the screen. when making wide range changes in the settings. ] METHOD Select [Setting range: 40 C/ 100 F ~ set heating temp ]...
  • Page 33: Set The Vacuum Level

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 8-4-10 Set the vacuum level 8-4-11 Select the maintenance mode Refer to "8-4-8 Select the vacuum pattern” and select When screen displays operation No. “3 Gauge”. (ex. [01] SEALING ONLY) Place the cursor to "3 Gauge" and push button. [ 01 ] SEALING ONLY The following display will be shown on the screen.
  • Page 34: Operation Procedures

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Operation procedures In this chapter, the flow of four operation patterns is explained. After setting the control unit, please proceed the operation according to the following 8-5-1 Seal only Operation number Change Move x.xs Heating time Heating temperature Cooling temperature Operation number Change Move...
  • Page 35 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Set the cooling temperature. Refer to “8-4-7 Set the cooling temperature. [Setting range: 40°C/100°F ~ set heating temperature] Set a pouch on the sealing position. Pressure lever descends and fasten a pouch with sponge rubber. (Keep Attention If leg is separated from the foot switch in the middle of downward, the pressure lever will open for the safe mechanism.
  • Page 36: Vacuum (Manual) And Sealing

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-5-2 Vacuum (manual) and sealing Operation number Change Move V MANUAL Vacuum by manual x.xs Heating time Heating temperature Cooling temperature Operation number Change Move V MANUAL Vacuum by manual x.xs Heating time Heating temperature Cooling temperature Procedure Reference page or description Circuit breaker ON.
  • Page 37 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E The nozzle will come forward. Set a pouch on the sealing position. Pressure lever descends and fasten a pouch with sponge rubber. (Keep Attention If leg is separated from the foot switch in the middle of downward, the pressure lever will open for the safe mechanism.
  • Page 38: Vacuum (Timer) And Sealing

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-5-3 Vacuum (timer) and sealing Operation number Change Move VT xx.xsec Vacuum by timer and set-up value x.xs Heating time Heating temperature Cooling temperature Operation number Change Move VT xx.xsec Vacuum by timer and set-up value x.xs Heating time Heating temperature Cooling temperature Procedure...
  • Page 39 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Set the cooling temperature. Refer to “8-4-7 Set the cooling temperature. [Setting range: 40°C/100°F ~ set heating temperature] The nozzle will come forward. Set a pouch on the sealing position. Pressure lever descends and fasten a pouch with sponge rubber. (Keep Attention If leg is separated from the foot switch in the middle of downward, the pressure lever will open for the safe...
  • Page 40: Vacuum (Gauge) And Sealing

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 8-5-4 Vacuum (gauge) and sealing Operation number Change Move Vacuum by vacuum gauge and set-up value VG- xxkpa x.xs Heating time Heating temperature Cooling temperature Operation number Change Move VG- xxkpa Vacuum by vacuum gauge and set-up value x.xs Heating time Heating temperature Cooling temperature...
  • Page 41 FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Set the cooling temperature. Refer to “8-4-7 Set the cooling temperature. [Setting range: 40°C/100°F ~ set heating temperature] The nozzle will come forward. Set a pouch on the sealing position. Pressure lever descends and fasten a pouch with sponge rubber. (Keep Attention If leg is separated from the foot switch in the middle of downward, the pressure lever will open for the safe...
  • Page 42: Replacing The Routine Maintenance Parts

    Do not replace parts according to other methods not described in the operating instructions. It is Warning dangerous if incorrect methods are used. When replacing parts, always use specified parts sold through Van der Stahl Scientific. Otherwise Warning malfunction may occur.
  • Page 43: Slide A Lower Fluoro Glass Sheet

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Slide a lower fluoro glass sheet Fluoro glass sheet holder [Replace when] When the fluoro glass sheet breaks, burns, or when the seal becomes messy, etc. [Essential tools] Scissors Loose the four plastic nuts (white) securing the fluoro glass sheet holder and sponge holder. Turn the fluoro glass sheet roll bar.
  • Page 44: Replace Center-Dry Tape (For Double-Side Heating Models)

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Replace center-dry tape (For double-side heating models) This chapter explains how to change the center-dry tape adhered to the upper pressure lever. [Replace when] When the fluoro glass sheet breaks, burns, or when the seal becomes messy, etc. Pressure lever [Essential tools] Scissors, slotted screwdriver E-ring Lift up the frame cover.
  • Page 45: Replace A Heating Element

    For your safety always attach the electrode Caution cover after installing the heating element. Always use a Van der Stahl designated, special heating element for replacement. Using a heating element other than the designated heating element may cause the transformer to be heat-damaged.
  • Page 46: Replace Glass Tape (19Mm: Pressure Lever/ 25Mm: Seal Receiving Plate) And Sarcon Sheet

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Replace glass tape (19mm: pressure lever/ 25mm: seal receiving plate) and Sarcon sheet [Replace when] The heating element breaks often, the seal becomes messy, etc. [Essential tools] Phillips screwdriver, Scissors, About 2mm About 2mm Industrial alcohol (Ethanol) The glass tape and Sarcon sheet are sold individually or Seal area length included in the maintenance parts kit.
  • Page 47: Replace A Silicone Rubber (For Single-Side Heating Models)

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Replace a silicone rubber (For single-side heating models) [Replace when] The silicone rubber become uneven. [Essential tools] Industrial alcohol (Ethanol) Remove two types of glass tapes adhered to the pressure lever. Remove the damaged silicone rubber. Pressure lever Using an industrial alcohol, etc., completely Silicone rubber remove the adhesive residues remaining on the Glass tape 50mm width...
  • Page 48: Replace 50Mm-Width Glass Tape (For Single-Side Heating Models)

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Replace 50mm-width glass tape (For single-side heating models) [Replace when] The heating element breaks often, the seal becomes messy, etc. [Essential tools] Scissors After adhering the silicone rubber, cut the new 50mm-width glass tape 2cm longer than the Pressure lever silicone rubber length.
  • Page 49: Connect And Remove Tube

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Connect and remove tube When remove the tube, press the release ring while Pay attention to the distance pushing the tube. between the release ring and body 21mm Body Release ring press there to remove the tube ■ How to remove the tube Tube If you press the release ring while pushing the tube in at the same time, you can remove the tube quite easily.
  • Page 50: Replace A Vacuum Nozzle

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 9-11 Replace a vacuum nozzle [Essential tools] Spanner Take off the frame cover. Remove the elbow from the nozzle. Push the open ring to horizontal direction with Nozzle supporter Elbow nozzle, then lock will be canceled. Open ring Loosen the bolt on the of nozzle supporter by the spanner.
  • Page 51: Replace A Temperature Sensor For Fas-402-Ch/ Fas-402-Ch-10D

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 9-12 Replace a temperature sensor for FAS-402-CH/ FAS-402-CH-10D [Replace when] Temperature sensor is damaged. Screw A-2 Screw B [Essential tools] Phillips screwdriver Temperature sensor The temperature sensor is positioned so that it slides in between the heating element and the glass tape. Screw A-1 The temperature sensor is attached on the right end of the pressure lever.
  • Page 52: Replace A Temperature Sensor For Fas-602-Ch/ Fas-602-Ch-10D

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 9-13 Replace a temperature sensor for FAS-602-CH/ FAS-602-CH-10D [Replace when] Temperature sensor is damaged. [Essential tools] Phillips screwdriver Heating element The temperature sensor is positioned so that it slides in between the heating element and the glass tape. Screw A-1 The temperature sensor is attached on the right end of the pressure lever.
  • Page 53: Specification

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 10 Specification Commodity name Nozzle type vacuum sealer Model name FAS-402-CH FAS-402-CH-10D FAS-602-CH FAS-602-CH-10D Power source * Note 1 Maximum power 2.6kW 2.9kW consumption Power cord * Note 2 Air source Compatible air compressor: 0.75kW, 80L/min, 0.5MPa or greater Air pressure setting value: 0.35 MPa Vacuum source Control style...
  • Page 54: Appearance Dimensions Drawing

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E Appearance dimensions drawing FAS-402-CH, FAS-402-CH-10D Air regulator Duct flange for the concentrated 真  空  計 -100kpa MENU 脱  気  中 exhaust ガス充填中 -50kpa 加  熱  中 冷  却  中 -10kpa Unit ; mm Circuit breaker Seal position FAS-602-CH, FAS-602-CH-10D Air regulator Duct flange for the concentrated 真  空  計 MENU -100kpa 脱  気  中...
  • Page 55: Specifications Of Accessories

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 11 Specifications of accessories Air pump Parts name Type Details at out of rating Vacuum air : 40-48L/min Air pump Vacuum degree : -88.3kPa Supply air : 40-48L/min Air parts Parts name Type Standard life and remarks Cylinder CDQ2B63-30DZ-M9BV 500,000 times or 3 years Cylinder CDQ2B63-30DZ-M9BVS Cylinder CQ2B32-25DZ...
  • Page 56: Regular Check And Maintenance

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 12 Regular check and maintenance For longer the sealer life and normally operation, it is necessary to check and maintain the sealer regularly. Please perform the checking and maintenance on time after purchased the sealer. 12-1 Regular check Checking items for every day Seal area Checking items for every week Fluoro glass sheet...
  • Page 57: Clean The Air Filter

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 12-2 Clean the air filter The air filter is located in-between the nozzle and the vacuum pump, stores any foreign objects accidentally taken in though the nozzle in filter cup. Be sure to check and clean cup everyday before the operation.
  • Page 58: Electric Diagram

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 13 Electric diagram 13-1 FAS-402-CH (110V) AC110V Ground terminal Circut breaker 110V Safety 105V circuit V402(110V) ELECTRIC DIAGRAM SPE_B00458 Air Pump Micro Switch Red Lamp Clear Lamp Transformer Heater Printer Temprature sensor AC100V AC100V Nozzle Back Position SOL.Y5 Vacuum Valve Lever lower position SOL.Y4 Nozzle forward...
  • Page 59: Fas-402-Ch (220V), Fas-402-Ch-10D, Fas-602-Ch, Fas-602-Ch-10D

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E 13-2 FAS-402-CH (220V), FAS-402-CH-10D, FAS-602-CH, FAS-602-CH-10D AC220V Ground terminal Circut breaker 220V 105V Safety circuit V402(220V) ELECTRIC DIAGRAM STE_B10864E Air Pump Micro Switch Red Lamp Clear Lamp Transformer Heater Temprature sensor Printer (In the case of double) AC100V AC100V Nozzle Back Position SOL.Y5 Vacuum Valve...
  • Page 60: Piping Diagram

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 14 Piping diagram CDQ2B63-30DZ-M9BVS digital vacuum gauge CDQ2B63-30DZ-M9BV CDM2BZ25-75AZ-H7BS CQ2B32-25DZ Nozzle Sealing section LS.X4 Nozzle cylinder Air regulator Rapid exhaust valve SOL.Y3 SOL.Y2 SOL.Y4 SOL.Y1 Filter VK3120-1H-01x2 VK-332-1H-01x2 SOL.Y5 200E1-21 PL8-02 Pump DOP-80SC Exhaust duct PL12-02 Air source AW30-02BDE-NR 60 60...
  • Page 61: Common Problems And Solution

    Carefully follow the directions in the operating instructions when replacing parts. Please consult Van der Stahl Scientific if after referring to the chart, the problem cannot be resolved. Please refer any questions regarding replacement of parts not listed in the operating instructions or adjustment of such parts to Van der Stahl Scientific.
  • Page 62 ON? Items marked with an asterisk * in the "Solutions" column refer to the fact that these problems should be addressed by electrician. If there are any problems, please contact Van der Stahl Scientific.
  • Page 63: Error Message 1

    Lamp for SSR-03 (xxx : 110 or 220) Items marked with an asterisk * in the "Solutions" column refer to the fact that these problems should be addressed by electrician. If there are any problems, please contact Van der Stahl Scientific.
  • Page 64: Error Message 2

    Consult with your dealer or our heating, this message is displayed. company. Items marked with an asterisk * in the "Solutions" column refer to the fact that these problems should be addressed by electrician. If there are any problems, please contact Van der Stahl Scientific.
  • Page 65: About The Maintenance Mode

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E About the maintenance mode The state of a machine is found by display in the maintenance mode. When the trouble occurs, we recommend to display the MAINTENANCE maintenance mode. The position of black marked X and Y told operator the trouble pattern.
  • Page 66: Exploded View Of The Maintenance Mode

    FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E 16 Exploded view of the maintenance mode Sealing section Sponge rubber holder (upper) Sealing plate Sponge rubber Electrode Sponge rubber holder (lower) Inside of the frame cover Control unit Digital vacuum gauge Circuit breaker SSR-03 Fuse 66 66...
  • Page 67: Nozzle Unit Section

    FAS-402-CH/FAS-602-CH Series Operating Instructions Ver. 1.05E Nozzle unit section Nozzle supporter Nozzle Air unit section Air pump Vacuum solenoid valve Nozzle valve Inside of the bottom plate Cylinder (big) Cylinder (small) Nozzle cylinder Transformer Auto transformer 67 67...
  • Page 68 Represented by 1652 Plum Lane, Redlands, CA 92374 800-550-3854  APR 2016 1st Edition www.vanderstahl.com FAS-402/602-CH Series Operating Instructions Ver. 1.05E...

This manual is also suitable for:

Fas-602-ch seriesFas-402-chFas-402-ch-10dFas-602-chFas-602-ch-10d

Table of Contents