Van Der Stahl V-460 Series Operating Instructions Manual

Microcomputer controlled tabletop nozzle type vacuum sealer
Table of Contents

Advertisement

MICROCOMPUTER CONTROLLED TABLETOP NOZZLE TYPE
VA CUUM SEA LER
V-460/610 SERIES
OPERATING INSTRUCTIONS
www.vanderstahl.com
Printed MAR 2017
2nd Edition 2.04E
B TYPE

Advertisement

Table of Contents
loading

Summary of Contents for Van Der Stahl V-460 Series

  • Page 1 Printed MAR 2017 2nd Edition 2.04E MICROCOMPUTER CONTROLLED TABLETOP NOZZLE TYPE VA CUUM SEA LER V-460/610 SERIES OPERATING INSTRUCTIONS B TYPE www.vanderstahl.com...
  • Page 2 V-460/610 Series Operating Instructions Ver.2.04E Thank you for purchasing V-460/610 series sealer! V-460/610 series is a table-top vacuum sealer controlled by the microcomputer, which makes it possible to set up the various operation patterns that the customers require. This manual explains the terms that is used when setting the seal conditions. Please read this manual thoroughly before use for the better understanding on how to set up/operate the V-460/610 series.
  • Page 3 V-460/610 Series Operating Instructions Ver.2.04E Foreword Please read all of the safety and operating instructions before operating this machine. Periodic maintenance and proper operation are necessary to ensure safety when using this impulse sealer. Keep this manual on hand when operating the sealer. Set the heating time according to the material and thickness of the film.
  • Page 4: Table Of Contents

    V-460/610 Series Operating Instructions Ver.2.04E Table of Contents Package contents …………………………………………………………………………………… 6 Warning-caution label location and content …………………………………………………… 7 Operating precautions ……………………………………………………………………………… 9 For safety operating ……………………………………………………………………………………………………………………… 9 For smooth operation …………………………………………………………………………………………………………………… 11 Other safeguards ………………………………………………………………………………………………………………………… 12 About the I-heating element …………………………………………………………………………………………………………… 13 Outline of structure ………………………………………………………………………………...
  • Page 5 V-460/610 Series Operating Instructions Ver.2.04E Operation procedures …………………………………………………………………………………………………………… 40 8-5-1 Operation procedures «SEAL ONLY»…………………………………………………………………………………… 40 8-5-2 Operation procedures «MANUAL VAC + SEAL» ……………………………………………………………………… 42 8-5-3 Operation procedures «TIMER VAC + SEAL» ………………………………………………………………………… 44 8-5-4 Operation procedures «VACUUM GAUGE VAC + SEAL» …………………………………………………………… 46 Replacing the routine maintenance parts ……………………………………………………...
  • Page 6: Package Contents

    5 Others Vacuum gauge instruction manual ※ ····1 pc. If anything is missing or damaged, contact Van der Stahl Scientific. Contents of package may vary depending on the machine model you have ordered. ※ For how to operate a vacuum gauge, please refer to the vacuum gauge manual.
  • Page 7: Warning-Caution Label Location And Content

    V-460/610 Series Operating Instructions Ver.2.04E Warning-caution label location and content Warning - caution labels are placed in locations where there is a danger of injury to a person or damage to the machine. Label location details are illustrated below. Please check them before beginning operation. Labels not readily apparent are indicated by dotted lines.
  • Page 8 V-460/610 Series Operating Instructions Ver.2.04E Warning-Caution label location and content (Cont’d) Body cover and pressure lever WARNING Electrical Shock or Burn Hazard - High Voltage. Unplug this device before opening this cover. W1265 W1173 When carrying the main unit, do NOT lift it by its seal lever. W1264 W1266 W1428...
  • Page 9: Operating Precautions

    V-460/610 Series Operating Instructions Ver.2.04E Operating precautions For safety operating In an emergency, unplug the power cord Warning immediately The V-460/610 series incorporates a number of safety devices and is carefully designed to prevent fires or other malfunctions. However, should all of the safety devices fail simultaneously, there is a possibility of the center-dry tape catching fire due to a failure of the heating circuit's tripping mechanism that results in the heating element overheating.
  • Page 10 Do not use parts other than those specified Warning When replacing parts, always use only specified parts sold through Van der Stahl Scientific. Not responsible for malfunctions caused by the use of unspecified parts. If the circuit breaker automatically turns to the OFF...
  • Page 11: For Smooth Operation

    V-460/610 Series Operating Instructions Ver.2.04E Do not use in the following places Caution Do not operate the machine in the places with high humidity and/or where the water/vapor can spill on the machine. The machine parts may become rusted. There is a danger of electrocution and/or machine malfunction due to the insulation failure.
  • Page 12: Other Safeguards

    V-460/610 Series Operating Instructions Ver.2.04E Allow sufficient cooling With an impulse type sealer, residual heat after the heating cycle has been completed is dispersed through the pressure lever and machine frame, allowing the film to set under pressure. Setting the cooling temperature excessively low will reduce the work efficiency.
  • Page 13: About The I-Heating Element

    V-460/610 Series Operating Instructions Ver.2.04E About the I-heating element ● The I-heating element installed to V-460/610 series V-460/610 series is installed with the I-heating element, which is made of material whose thermal expansion is minimal. Features of the I-heating element: Because the I-heating element expands less during heating compared to conventional heating elements, they are less likely to break, such as in the middle of the heating element.
  • Page 14: Outline Of Structure

    V-460/610 Series Operating Instructions Ver.2.04E Outline of structure The V-460/610 is a tabletop impulse sealer equipped Place a pouch Sealing section with a nozzle for removing air. Sponge rubber When the nozzle is inserted into a bag, the bag will be securely locked by sponge-rubber strips covering the sealing jaws, and the air in the bag will be removed by Table...
  • Page 15: Major Parts And Function

    V-460/610 Series Operating Instructions Ver.2.04E Major parts and function Frame cover Printer outlet Open the frame cover Vacuum gauge to perform machine Refer to a vacuum gauge Control unit maintenance. manual included in accessories for the detail. Air filter Emergency Store any objects taken in stop switch though the nozzle such as...
  • Page 16 V-460/610 Series Operating Instructions Ver.2.04E Control unit ⑨ ⑧ ④ ⑦ ⑤ ⑥ ③ ⑩ ⑪ ② ① ① Power button ③ MENU button Push to turn ON or OFF the power. (When circuit breaker is Push to show MENU mode. ON.) ④⑤⑥⑦...
  • Page 17: Proper Use Of The Sealer

    V-460/610 Series Operating Instructions Ver.2.04E Proper use of the sealer Secure the work place For safety and efficient operation, please set the sealer in the appropriate place as described below. Installing the machine on an unstable or Warning inclined surface may cause the overturn of the sealer.
  • Page 18: Set An Air Pedal

    V-460/610 Series Operating Instructions Ver.2.04E Set an air pedal Insert an air pedal hose securely into the elbow of the Securely insert the hose main frame air switch located on the left side of the machine. Body frame air switch Air hose with elbow joint Attach/remove the table and how to...
  • Page 19: Nozzle Position Adjustment

    V-460/610 Series Operating Instructions Ver.2.04E Nozzle position adjustment ■ Preparation Remove two screws that fix the frame cover. Raise the Remove screws frame cover to open it. Frame cover ■ Adjust nozzle angle You can adjust the nozzle angle according to your packaging needs.
  • Page 20: Test Emergency Stop System

    If the circuit breaker does NOT turn OFF Warning by pressing the emergency stop switch, follow the below instructions and contact Van der Stahl Scientific. Press a test button of the circuit breaker as in the right illustration. Test button When the circuit breaker turns OFF: the emergency stop switch may be broken.
  • Page 21: Set The Seal Conditions With The Control Unit

    V-460/610 Series Operating Instructions Ver.2.04E Set the seal conditions with the control unit Please refer to “8 Control unit setting and operating for the detail. procedures” Test sealing After setting the seal conditions at the control unit, hold the bag by both hands and stretch it tight. Set the bag between seal levers.
  • Page 22: Control Unit Setting And Operating Procedures

    V-460/610 Series Operating Instructions Ver.2.04E Control unit setting and operating procedures This chapter is composed with the following sections: Operate the machine with the pre-installed operation patterns This chapter explains how to operate the V-460/610 series with the pre-installed operation patterns to give you the general idea of how to operate the machine properly.
  • Page 23: Operate The Machine With Pre-Installed Operation Patterns

    V-460/610 Series Operating Instructions Ver.2.04E Operate the machine with pre-installed operation patterns Two operation patterns are pre-installed to the V-460/610 series at the time of factory shipment. The sealing parameters of the pre-installed operation patterns (heating temperature etc.) can be  Attention changed depending on the customer application.
  • Page 24: Sample Operating Procedures : "Seal Only" Operation

    V-460/610 Series Operating Instructions Ver.2.04E 8-1-1 Sample operating procedures : “seal only” operation Operation No.[01] SEAL ONLY The seal parameters set at the time of factory shipment: HT : 140ºC/280ºF, CT : 100ºC/200ºF = Refer to “8-5 Operation procedures >>> 8-5-1 Operation procedures <<SEAL ONLY>>.” The machine automatically performs the following If any change has been made to the TIPS...
  • Page 25: Sample Operating Procedures : "Manual Vacuum + Sealing" Operation

    V-460/610 Series Operating Instructions Ver.2.04E 8-1-2 Sample operating procedures : “manual vacuum + sealing” operation Operation No.[02] VAC & SEAL manual The seal parameters set at the time of factory shipment: HT : 140ºC/280ºF, CT : 100ºC/200ºF = Refer to “8-5 Operation procedures >>> 8-5-2 Operation procedures <<MANUAL VAC + SEAL>>.” If any change has been made to the 7 Place a bag to the sealing area TIPS...
  • Page 26 V-460/610 Series Operating Instructions Ver.2.04E (“Manual vacuum + sealing” operation” Cont’d) ・ The pressure lever descends completely. (Sealing starts.) ・ After the heating is complete (heating lamp is turned off), cooling lamp turns on. ・ Cooling is complete (cooling lamp turns off). ・...
  • Page 27: Register Sample Operation Patterns

    V-460/610 Series Operating Instructions Ver.2.04E Register sample operation patterns Maximum 10 operation patterns can be stored in the control unit.  Attention If you are going to register over 10 operation patterns, the message “ALL 10 OPERATION PATTERNS ARE ENTERED. DELETE ONE FOR A NEW ENTRY.“ is displayed on the screen. You cannot input a new operation pattern until at least one of the stored operation pattern is deleted.
  • Page 28: Sample Case: Register A "Seal Only" Operation Mode

    V-460/610 Series Operating Instructions Ver.2.04E 8-2-1 Sample case: register a “seal only” operation mode TIPS The following operation procedures are for the new machine without any change on the setting. Let’s register “sealing only” operation to operation number [03]. Operation setting : heating temperature 140ºC/280ºF, heating time 0.3 seconds, cooling temperature 100ºC/200ºF 1 Turn ON the circuit breaker.
  • Page 29: Sample Case: Register A "Timer Vacuum + Seal" Operation Mode

    V-460/610 Series Operating Instructions Ver.2.04E 8-2-2 Sample case: register a “timer vacuum + seal” operation mode TIPS The following operation procedures are for the new machine without any change on the setting. Let’s register “timer vac + seal” operation to operation number [03].. Operation setting : heating temperature 140ºC/280ºF, heating time 0.3 seconds, cooling temperature 100ºC/200ºF, vacuum timer 12.0 seconds 1 Turn ON the circuit breaker.
  • Page 30: Explanation Of Terms

    V-460/610 Series Operating Instructions Ver.2.04E Explanation of terms This chapter explains the terms used in this manual and basic knowledge about Van der Stahl's impulse sealers. Impulse sealer There are four sealing methods depending on your purpose and usage. Sealers refer to machines in general that seal the opening or loose ends of plastic- called heat sealers.
  • Page 31: How To Set The Control Unit

    V-460/610 Series Operating Instructions Ver.2.04E How to set the control unit Explanation of each button on the control panel The following buttons are used to set seal conditions. MENU button =  Press to show following menus on the display: “1 entry,” “2 change,” “3 delete,” “4 NZ stroke,”...
  • Page 32: Seal Counter

    V-460/610 Series Operating Instructions Ver.2.04E NOTES: The following explains on condition circuit breaker and the power switch are ON. The numeric values on the control unit display is described as “xx” The cursor position is described as . mark on the control unit display indicates the different contents by each operation number. “...
  • Page 33: Delete A Registered Operation Pattern

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-4 Delete a registered operation pattern Move the cursor to the desired operation You can cancel deletion by pressing a TIPS button if it has not yet confirmed mode between “1 SEAL” and “2 SEAL + by pressing a button.
  • Page 34: Set Heating Temperature

    V-460/610 Series Operating Instructions Ver.2.04E The cursor will blink at the first digit of When one operation number is deleted, TIPS the following numbers will move “HT.” When the cursor is at this position, forward automatically. adjust the heating temperature by pressing: E.g.) to increase the value.
  • Page 35: Set Heating Time

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-6 Set heating time The value will increase or decrease in 0.1 seconds increment by pressing the button ■ How to change heating time of the once. If you hold the button in, the numeric currently displayed operation pattern: value will increase or decrease >>...
  • Page 36: Set Cooling Temperature

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-7 Set cooling temperature When the cursor is at this position, adjust the cooling temperature by pressing: ■ How to change cooling temperature to increase the value. of the currently displayed operation to decrease the value. pattern: >>...
  • Page 37: Select The Desired Vacuuming Mode

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-8 Select the desired vacuuming mode 8-4-9 Manual vacuum mode Referring to " See “ 8-4-8 Select the desired vacuuming 8-4-3 Register/change an operation ", place the cursor to "1 Manual" by pressing ” and select “2 VAC+SEAL” mode. mode pattern button and press the...
  • Page 38: Timer Vacuuming Mode

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-10 Timer vacuuming mode 8-4-11 Vacuum gauge vacuuming mode Referring to " Referring to " 8-4-8 Select the desired vacuuming 8-4-8 Select the desired vacuuming ", place the cursor to "2 Time" by pressing ”, place the cursor to "3 Gauge" by pressing mode mode button and press the...
  • Page 39: Setting Nozzle Stroke

    V-460/610 Series Operating Instructions Ver.2.04E 8-4-12 Setting nozzle stroke 8-4-13 Maintenance mode When the entered operation is displayed on Press the button and show the the control unit like the one in the below following display on the screen. illustration:      ...
  • Page 40: Operation Procedures

    V-460/610 Series Operating Instructions Ver.2.04E Operation procedures This chapter explains 4 combinations of operating procedures. Select a sealing method to meet your needs, including selecting to best suit the characteristics of the packaged material and to obtain your desired packaging finish. 8-5-1 Operation procedures «SEAL ONLY»...
  • Page 41 V-460/610 Series Operating Instructions Ver.2.04E ("SEAL ONLY" operation cont’d) Depress an air pedal. 1 A pressure lever closes (sealing starts). 2 Heating lamp turns ON. 3 After the heating is finished (heating lamp is turned OFF), cooling lamp turns ON. 4 Cooling is finished.
  • Page 42: Operation Procedures "Manual Vac + Seal

    V-460/610 Series Operating Instructions Ver.2.04E 8-5-2 Operation procedures «MANUAL VAC + SEAL» Display Operation number   [xx] ▼ ▲ Dec/ In c      M ove       VAC MANUAL Vacuum mode =1Manual  HT xx C  x. xs CT  x x Heat temp Heat time Cool temp Operation number  ...
  • Page 43 V-460/610 Series Operating Instructions Ver.2.04E Place a pouch to the seal area. Place a pouch to the seal area and insert the vacuum nozzle in it. Stretch the pouch out by pulling both sides by hands. Depress the air pedal. (2nd) A pressure lever descends and fastens a pouch with sponge rubbers.
  • Page 44: Operation Procedures "Timer Vac + Seal

    V-460/610 Series Operating Instructions Ver.2.04E 8-5-3 Operation procedures «TIMER VAC + SEAL» Display Operation number   [xx] ▼▲ D ec /I n c         Mov e       VAC TIME  xx.xsec The vacuum level is determined by setting the vacuuming time.  HT xx C  x . xs  CT  Heat temp Heat time Cool temp...
  • Page 45 V-460/610 Series Operating Instructions Ver.2.04E [Setting range: 40°C/100°F ~ Up See “8-4 How to set the control unit” >>> “8-4-7 Set cooling to the set heating temperature temperature”. by the user] Depress an air pedal. (1st) The vacuum nozzle moves forward. Place a pouch to the seal area.
  • Page 46: Operation Procedures "Vacuum Gauge Vac + Seal

    V-460/610 Series Operating Instructions Ver.2.04E 8-5-4 Operation procedures «VACUUM GAUGE VAC + SEAL» Display Operation number   [xx] ▼▲ D ec /I n c         Mov e       VAC GAUGE  -xxkPa Vacuuming by setting the desired vacuum level in kPa. The vacuum level will be shown on the digital  HT xx C x.xs CT xx...
  • Page 47 V-460/610 Series Operating Instructions Ver.2.04E [Setting range: 40°C/100°F ~ Up See “8-4 How to set the control unit” >>> “8-4-7 Set cooling to the set heating temperature temperature”. by the user] Depress an air pedal. (1st) The vacuum nozzle moves forward. Place a pouch to the seal area.
  • Page 48: Replacing The Routine Maintenance Parts

    Do not replace parts according to other methods not described in the operating instructions. It Warning is dangerous if incorrect methods are used. When replacing parts, always use only specified parts sold through Van der Stahl Scientific. Warning Otherwise malfunction may occur.
  • Page 49: Replacing The Center-Dry Tape On The Lower Lever (For All Models)

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the center-dry tape on the lower lever (for all models) Replace the center-dry tape adhered to the seal receiving plate (lower lever) to the new one. [Replace when] When the center-dry tape is breaks, burns, or when the seal becomes messy, etc.
  • Page 50: Replacing The Center-Dry Tape On The Upper Lever (For Double-Side Heating Models)

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the center-dry tape on the upper lever (for double-side heating models) Replace the center-dry tape adhered to the pressure lever (upper lever) to the new one. [Replace when] When the center-dry tape is breaks, burns, or when the seal becomes messy, etc.
  • Page 51 V-460/610 Series Operating Instructions Ver.2.04E Using scissors, cut the new center-dry tape in a length 10mm longer than the length of the pressure lever (5mm each to the left and right). Sponge holder Pressure lever Fold the center-dry tape along edges so that the excess tape over the seal receiving plate adheres to the other side of the plate.
  • Page 52: Replacing I-Heating Element

    For your safety always attach the electrode cover Warning after installing the heating element. Always use a Van der Stahl designated, special heating element for replacement. Using a heating element other than the designated heating element may cause the transformer to be heat- damaged.
  • Page 53: Replacing 25Mm-Width Glass Tape And Sarcon Sheet On The Lower Lever (For All Models)

    V-460/610 Series Operating Instructions Ver.2.04E Replacing 25mm-width glass tape and Sarcon sheet on the lower lever (for all models) [Essential tools] Scissors, Phillips screwdriver [Replace when] The heating element breaks often, the seal becomes messy, etc. If the glass tape and/or Sarcon sheet is Caution damaged, it may result in bad sealing or defective insulation of heating element.
  • Page 54: Replacing The Silicone Rubber And 38Mm-Width Glass Tape (For Single-Side Heating Type)

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the silicone rubber and 38mm-width glass tape (for single- side heating type) [Essential tools] Industrial-purpose alcohol (ethanol), Pressure lever Scissors Silicone rubber [Replace when] The surface of silicone rubber is uneven. 38mm width glass tape The heating element breaks often, the seal becomes messy, etc.
  • Page 55: Replacing The Silicone Rubber (For Double-Side Heating Type)

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the silicone rubber (for double-side heating type) [Essential tools] Industrial-purpose alcohol (ethanol) Pressure lever [Replace when] The surface of silicone rubber is uneven. Silicone rubber Remove the center-dry tape, heating element, glass tape and Sarcon sheet as described in their respective replacement instructions.
  • Page 56: Replacing The Vacuum Nozzle

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the vacuum nozzle Nozzle holder [Essential tools] Hexagonal wrench ■ Remove a vacuum nozzle Cap bolt Lift the frame cover up to open it. Loosen a cap bolt of the nozzle holder using a Vacuum nozzle hexagonal wrench.
  • Page 57: Replacing The Temperature Sensor

    V-460/610 Series Operating Instructions Ver.2.04E Replacing the temperature sensor [Replace when] Temperature sensor is damaged [Essential tools] Phillips screwdriver Temperature sensor module The temperature sensor is positioned so that it slides in Screw A-1 between the heating element and the glass tape. The temperature sensor is attached on the right end of Screw A-2 the pressure lever.
  • Page 58: Specification

    V-460/610 Series Operating Instructions Ver.2.04E 10 Specification ! Power Vacuum Vacuum Exhaust Ultimate Machine Seal Seal ① Model name Power Seal method consumption pump method speed vacuum drive length width V-460(C)-5 1.3kW Single-side 110V/ heating V-460(C)-10 1.5kW 10mm 220V ‐87.0kPa 50RNS 39L/min 460mm...
  • Page 59 V-460/610 Series Operating Instructions Ver.2.04E     ! ! Heat Heat Vacuum Nozzle Cool Vacuum Machine Seal Table ② ① Model name Weight dimensions height dimensions temp dwell temp time setting stroke 55k g V-460(C)-5 55k g V-460(C)-10 55k g V-460(C)-5D 60k...
  • Page 60: Safety Measures

    V-460/610 Series Operating Instructions Ver.2.04E Safety measures a) When power continues to be distributed to the heating element for about 4.5 seconds or more, the breaker turns off automatically and the power shuts off. Overheating prevention b) When an increase in temperature is detected during the cooling process, the lever will be released to return to its initial position and an error message will be displayed on the control unit.
  • Page 61 V-460/610 Series Operating Instructions Ver.2.04E...
  • Page 62: Appearance Dimensions Drawing

    V-460/610 Series Operating Instructions Ver.2.04E Appearance dimensions drawing V-460 series Unit :mm Seal position V-610 series Unit :mm Seal position...
  • Page 63 V-460/610 Series Operating Instructions Ver.2.04E V-460C series Duct bracket for centralized exhaust Unit :mm Seal position V-610C series Duct bracket for centralized exhaust Unit :mm Seal position...
  • Page 64: Maintenance

    Replace the tubes as necessary. ※ 2 Van der Stahl Scientific performs temperature calibration before the factory shipment; however, the actual temperature may gradually change by using the machine. Calibrate the heating temperature periodically to use the machine in the optimum condition.
  • Page 65: Cleaning The Air Filter

    V-460/610 Series Operating Instructions Ver.2.04E 11-2 Cleaning the air filter The air filter is located between the vacuum nozzle and vacuum pump, storing any foreign objects accidentally taken in though the nozzle inside the filter cup. Be sure to check and clean the filter cup everyday before starting the operation.
  • Page 66: Electric Diagram

    V-460/610 Series Operating Instructions Ver.2.04E 12 Electric diagram 110V...
  • Page 67: 220V

    V-460/610 Series Operating Instructions Ver.2.04E 220V...
  • Page 68: Piping Diagram

    V-460/610 Series Operating Instructions Ver.2.04E 13 Piping diagram V-460/610 series...
  • Page 69: V-460/610C Series

    V-460/610 Series Operating Instructions Ver.2.04E V-460/610C series...
  • Page 70: Common Problems And Solution

    Carefully follow the directions in the operating instructions when replacing parts. Please consult Van der Stahl Scientific if after referring to the chart, the problem cannot be resolved. Please refer any questions regarding replacement of parts not listed in the operating instructions or adjustment of such parts to Van der Stahl Scientific.
  • Page 71: Error Display 1

    V-460/610 Series Operating Instructions Ver.2.04E Problems Check Solution ※ Check if the correct voltage is provided to the power source side. Does the circuit breaker trip while heating? ※ Control unit may be damaged. Replace the control unit. The circuit breaker trips. ※...
  • Page 72: Error Display 2

    V-460/610 Series Operating Instructions Ver.2.04E 14-2 Error display 2 Error message Cause Solution X1 SENSOR PROBLEM The X1 sensor damaged or disconnected. Press ENT to escape X1 LEVER UPPER Lever upper position error Press ENT to escape X2 LEVER SPONGE Lever sponge position error Press ENT to escape ※...
  • Page 73: Error Display 3

    Check which number(s) of X (input) and Y (output)  x   is/are indicated in the black.  y When contacting Van der Stahl Scientific, please tell (■=ON  □=OFF) us this information for our better understanding of the problem. You can check the detail of each input/output detail from “...
  • Page 74: Consumable Parts List

    V-460/610 Series Operating Instructions Ver.2.04E 15 Consumable parts list Consumable parts will be damaged as using the machine. Using the machine with damaged consumable parts will cause bad sealing and even damage to the machine. Keep some major consumable parts with you and replace them as necessary.
  • Page 75 V-460/610 Series Operating Instructions Ver.2.04E...
  • Page 76 Represented by 1652 Plum Lane, Redlands, CA 92374 800-550-3854 Y7019 MAR 2017 2nd Edition www.vanderstahl.com V-460/610 Series Operating Instructions Ver. 2.04E...

Table of Contents