Chroma 62000B Series User Manual page 47

Modular dc power supply
Table of Contents

Advertisement

Mode: 2.0B
Baudrate: 125Kbps (default)
Acceptance Code: 0x00200000
(Address=1)
Acceptance Mask: 0x00FF00FF
S
11-Bit
O
Identifier
F
ID28-ID18
The above figure is the packet format of CAN 2.0B. Users can map it to the example below
to understand the meaning of each column. To control the 62000B on Address, the ID
column can be got by the following conversion formula, see also CAN_Tx() Function in
section 4.4.5 Example Program:
ID = (PC_Address + (62000B_Address * (2 ^ 8))) * (2 ^ 13)
0x3FC000= (254 + (1 * (2 ^ 8))) * (2 ^ 13)
Example 1: SOUR:VOLT 12
ID=0000000100100000xxxxxxxxxxxxxb
DCL=8
RTR=0
DATA= " SOUR:VOL" +0x0A
S
I
18-Bit
R
D
Identifier
R
E
ID17-ID0
Extended CAN: 29-Bit Identifier (CAN 2.0 B) Bit Fields
Change mainframe voltage to 12V (Address 1)
Mode: 2.0B (29-bit)
Baudrate: 125Kbps
Acceptance Code: 0x1FC00000
(Address=254)
Acceptance Mask: 0x1FFFFFFF (accept all
message)
...
Figure 4-1
R
R
R
D
T
1
0
L
R
C
Communication Protocols
Mode: 2.0B
Baudrate: 125Kbps
Acceptance Code: 0x0DA00000
(Address=109)
Acceptance Mask: 0x00FF00FF
0-8 Bytes
C
A
Data
R
C
C
K
E
I
O
F
F
S
4-9