Chroma 62000B Series User Manual page 36

Modular dc power supply
Table of Contents

Advertisement

Modular DC Power Supply 62000B Series Operation Manual
Current Sharing
Wire
V Sense
Wire
The Remote Sensing Wire won't be damaged due to wrong polarity
CAUTION
connection at this time. Just follow the steps below:
1.
2.
3.
4.
5.
6.
3-6
Figure 3-3
First shut down the device.
Connect the remote sensing wire correctly.
Reboot the device.
Remote Sense needs to be connected to hardware properly when
DC Output is OFF. Do not remove or connect the Remote Sense
in DC ON state, or it may cause the hardware to misjudge when
doing voltage compensation and stop output after the DC Module
Fault LED is on for alarm.
Do not insert the DC Module back to the Mainframe connector right
away after removing it from the Mainframe connector in normal
operation mode. It is necessary to wait until the Fault LED on the
DC Module front panel is off to reinsert the DC Module.
Precautions when replacing the power module: Insert the power
module accordingly without hesitate and wait until the Output and
CANBUS
Wire
P C