Emergency Opening - PROMIX SM305 Operating Manual

Electromechanical lock
Table of Contents

Advertisement

Promix-SM305
the access restriction regime and other factors (the presence of security providers, video
surveillance, etc.).
2) To prevent deformations of the door due to attempts to open the door with the lock closed, it is
recommended to mount the lock in the area of the door handle.
3) It is recommended to install the lock together with a door closer – this reduces impact load on
the lock and extends its service life.
4) Operation of an installed NC lock should be tested only if the supply voltage can be applied
thereto.

7.1 EMERGENCY OPENING

There is an emergency exit rod in the lock case. To mechanically open the lock, pull the
rod, moving it to the "open" position (see Fig.10) and then open the door.
Emergency exit rod
7.2
LOCK TRANSFER FROM ONE VERSION TO
ANOTHER
Normally opened version
1
4
3
The lock transfer from the normally open to normally closed version:
1. Unscrew three fastening screws 1 and take off the base.
2. Take off the thrust 2 from the base.
3. Unscrew the fastening screw 3 and remove the bracket of the solenoid.
4. Unscrew the fastening screw 4 and remove the coil and the angle.
5. Withdraw the fastening screw 4 from the coil and insert it in the reverse side of the coil.
6. Fix the coil with the turned angle 5 on the bracket with the screw in the adjacent threaded hole.
7. Mount the bracket on the body and fix with the screw 3.
8. Mount the rest on the axle 2.
6
Normally closed version
1
4
2
3
Fig. 10
2
Fig. 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm305.00Sm305.10

Table of Contents