While connecting Control Source and Camera as below, please just add one 120Ohm Terminal Resistor
between Terminal A and B(take off JMP1 from the board).

4.8 Special Preset

Special functions as listed below can be realized by special preset positions. These presets can not be used for
common use and they are only the "Key" to special functions
Preset
Function
32
Start Position
33
Pan Rotation
34
Pan Zero Position
Sprayer Position
63
Definition
80
Open AUX1
81
Close AUX1
83
Start Preset Touring
Short Time Stay
84
Between Preset Touring
Normal Time Stay
85
Between Preset Touring
Long Time Stay
86
Between Preset Touring
90
Open AUX2
91
Close AUX2
92
Set Left Limit
93
Set Right Limit
94
Remote Reset
96
Stop Scan
Camera
A B Gnd
A B Gnd
Control
P20. "chrysanthemum" Connection of Cameras
T9. Special Presets
Startup Position when self-examination program finishes
Remote Reset and the camera will do the self-examination
SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual
Camera
A B Gnd
Description
Flip, Pan will rotate 180 degree
Zero, Pan rotates to zero point
Realized by closing Aux switch 1
Open AUX1 for starting wiper
Close AUX1 for starting sprayer
1~16 presets touring
Time for stay can be specified between 2 presets
Time for stay can be specified between 2 presets
Time for stay can be specified between 2 presets
Open AUX2
Close AUX2
Set Left Limit by preset 99
Set Right Limit by preset 99
Stop Scan
Camera
A B Gnd
120Ω