Summary of Contents for Veilux SVEX-W125-3

  • Page 1 YHW125-3 (Ex) Explosionproof PTZ Camera Manual Book ExdⅡCT6 / DIP A20 TA, T6 EX mark: Ver: 2.3 CNEx10.1195 Certificate No.: XK06-014-00898 License: Veilux SVEX-W125-3 Explosion Proof PTZ Camera...
  • Page 2 SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Please carefully read the Manual Book before your operation 1. Installation „ Please install under required environment „ Ensure stable and reliable mounting in case camera be damaged „ Ensure supply power same as nameplate marked before equipment being powered „...
  • Page 3: Table Of Contents

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 CONTEN T 1. BRIEF ..................4 2. TECHINICAL ................4 2.1 Type Code ................ 4 2.2 Certificate ................. 4 2.3 Electric Data ..............5 2.4 Camera Data ..............5 2.5 Mechanical ............... 5 2.6 Environmental ..............
  • Page 4: Brief

    Ver: 2.3 1. BRIEF This EXPLOSIONPROOF PAN TILT ZOOM CAMERA(therefore as SVEX-W125-3 Camera)as a new monitoring equipment adopts advanced production techniques and matured quality management system to make its quality, performance and appearance a leading position in explosion proof monitoring products. It can be used in flammable and explosive environment to realize monitoring purpose.
  • Page 5: Electric Data

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 License XK06-014-00898 2.3 Electric Data Input voltage 100~240VAC Working current < 1A Power consumption 85 W Electric connection 6-core cable for video, power and control signal Communication RS-485 Communication speed...
  • Page 6: Environmental

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Pan speed 0.1°/S~25°/S Tilt speed 0.1°/S~25°/S Unit weight 27Kg Ship weight 30Kg Mounting fixed bracket, base and pole 2.6 Environmental Air pressure 86~106KPa Environment temperature -40℃~+60℃ Relative humidity U95%RH (+25℃) 2.7 Dimension...
  • Page 7: Installation

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 3. INSTALLATION 3.1 Caution Please carefully check before installation a. If there is ex-marking license b. The ex-marking satisfy environment use c. All ex-proof and flameproof parts are complete enough for structure d.
  • Page 8: Bracket Mounting

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 3.3 Bracket Mounting Mount bracket SVEX-W125-3 Camera cable Junction box Cable tunnel or Cables go to Control bridge Room Tunnel Bridge Mount Bracket and Junction Box Mount Camera and Connect Cables...
  • Page 9 SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Cable out Ex cable Crew Cable out gasket base Tighten nut Rubber gasket b. as P8, remove tighten nut, keep standard gasket and rubber gasket, put on screw joint and ex cable...
  • Page 10: Application

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Ex-proof Gland Parts Armored cable Rubber Connection Protection Cover Cable inner layer Sealing Loop Bushing Bushing Joint Steel belt Cable core wire Gasket Taper Volt P10. b. As Picture 11, install Ex-proof Gland to Armored Cable, as the method please refer to Document for Installation of Ex-proof Gland.
  • Page 11: Cable Definition

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 P12. System Connection 4.2 Cable Definition While camera leaves factory, we supply a Composite Cable** with camera, the cable goes out from Camera bottom with length at least 2 meters. So while connection the system, just connect the cable with Junction Box.
  • Page 12: Address Set

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 4.3 Address Set TO SET BAUD RATE AND PROTOCOL ATTENTION FLAMEPROOF JOINT PROTECT SIDE COVER P13. COMMUNICATION SET Camera address adopts binary system, ON to1, OFF to 0. Normally address has been set down before camera leaving factory, but if there is need to adjust the address, please refer to Picture 13, open the Camera Top Cover as Table 2 to adjust the SW1 code for set again.
  • Page 13 SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3...
  • Page 14: Function Set

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 4.4 Function Set Please firstly confirm the communication protocol and Baud rate, then set SW2 according to Table 3,4 and 5. P15. Dip Switch SW2 4.4.1 Baud Rate Set Set the baud rate carefully according to communication requirements. It goes into effect when power on.
  • Page 15: Circuit Board Structure And Function Definition

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 SONY SANYO HONEYWELL 4.5 Circuit board structure and function definition This product has equipped special connection board for main circuit board to provide reliable connection and fix for cables. Connection board and main board connect through pins and the main board provides two connector jack to install extend function sub-board.
  • Page 16: Camera Connection

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Mark Name Function OB.RS:RS232, RS485 modes to control camera OB.RL : Relay output, voltage modes to control camera Address select code Address set switch Function select code Function set such as protocol, baud rate, etc...
  • Page 17: Control Signal Connection

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 camera on the bottom holes. Test the camera to see if there is any dead angle. Adjust the drawer layer to fix camera. There is wire connection board on the drawer layer, the definition is as follows: T8.
  • Page 18: Special Preset

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Camera Camera Camera A B Gnd A B Gnd A B Gnd 120Ω A B Gnd Control P20. “chrysanthemum” Connection of Cameras While connecting Control Source and Camera as below, please just add one 120Ohm Terminal Resistor between Terminal A and B(take off JMP1 from the board).
  • Page 19: Washer System

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 Start Preset Touring 1~16 presets touring Start Scan Start Scan between preset 92 and 93 4.9 Washer System 1253 camera window Cable outlet Water tank connected to camera Add water here...
  • Page 20: Flameproof Structure

    SVEX-W125-3 (Ex) Explosion proof PTZ Camera Manual Book Ver: 2.3 5. FLAMEPROOF STRUCTURE „ Completely consider the explosive air getting into ex-proof structure, which may lead to explosion because of some reason and to confirm and ensure camera explosion proof performance based on its structure gap, length and max temperature it will get to.
  • Page 21: Shipping And Storge

    Veilux owns the final design changing and final specification rights and no responsibility to inform user „ This manual book belongs to Veilux rights, without permits or any book inform, any company or private copy of whole or part of the book shall be prohibited. 802 GREENVIEW DR STE 200 GRAND PRAIRIE, TX.

Table of Contents