The Propane (LP) gas pressure regulator
CAUTION
and hose assembly supplied with the
heater must be used without alteration.
INSTALLATION
1. Inspect LP cylinder to ensure it is in good condition.
2. Connect power cord to electrical supply outlet.
3. Connect Gas supply hose to heater. Connect other end
(regulator) to a propane gas supply cylinder.
Use the appropriate LP cylinder listed
CAUTION
below.
ST-40-GFA-E : 9 Kg to 45 Kg cylinder
ST-50V-GFA-E : 9 Kg to 45 Kg cylinder
ST-100V-GFA-E : 9 Kg to 45 Kg cylinder
ST-150V-GFA-E : 9 Kg to 45 Kg cylinder
NOTE: Optimum efficiency is achieved when the heater uses
the appropriate full LP cylinder
4. Slowly open the LP cylinder. Leak test all gas connections with
50/50 soap and water solution prior to start-up. Soap bubbles
indicate a gas leak. DO NOT use a match or flame to test for
gas leaks.

LIGHTING INSTRUCTIONS

1. Switch the electrical power switch to ON and check if fan is
operating correctly.
2. Wait five (5) minutes for any gas to clear. Smell for gas. If none
is evident, proceed to the next step.
3. Push in and turn the Valve Knob to the LOW/IGN position
(HIGH/IGN on ST-40-GFA-E). This will light the burner. It may
be necessary to repeat this process a few times to light the
heater.
STANLEY and
EN
are trademarks of Stanley Black & Decker, Inc or its affiliates and are used under
license by Pinnacle Products International, Inc.
4. Keep the Valve Knob depressed for at least 30 seconds after
the burner is lit. After 30 seconds release the Valve Knob.
5. If burner does not stay lit, wait one minute and repeat Steps 3
and 4.
6. Once burner is lit, push in and turn Valve Knob to desired
setting (LOW/MED/HIGH), (ST-40-GFA-E only has one setting).

SHUTDOWN INSTRUCTIONS

1. Turn the control knob at the supply cylinder clockwise to the
CLOSED position.
2. Turn gas valve control knob on the heater to the OFF position.
3. Disconnect heater from power supply.

MAINTENANCE

-
Heater surface temperature must be cold before initiating
service, cleaning or storage.
-
Maintenance and repair must be carried out by trained person-
nel only.
-
Before commencing service maintenance disconnect the unit
from the electrical power and the gas supply.
-
Check the gas supply hose condition and change if necessary.
-
Check the ignition unit, safety thermostat, and thermocouple
condition and ensure that they are clean Wear eye protection
when performing these checks.
-
Clean inside the heater unit and the fan blade with
compressed air.