General DIP Switch Settings
Bypass
Nuisance
Irrevocable
Code
(Release)
Delay
Alarm
Delay
SW1
SW2
SW3
SW4
Sec
Sec
Standard
for all
other
Off
Off
Off
0
regions
Off
15
On
Off
1
On
(Factory
Setting
Off
On
2
Off
On
30
Bolded)
On
On
3
On
SW1
SW2
Sec
SW3
Sec
SW4
Off
Off
1
Off
Off
15
Chicago
On
Off
1
On
Off
On
1
Off
On
15
On
On
1
On
SW1
SW2
SW3
SW4
Sec
Sec
Off
Off
0
Off
California
Off
15
15
On
Off
1
On
Seconds
Off
On
2
Off
On
15
On
On
3
On
SW1
SW2
Sec
SW3
Sec
SW4
Off
Off
0
Off
California
Off
30
30
On
Off
1
On
Seconds
Off
On
2
Off
On
30
On
On
3
On
*May not be applicable to specific Chicago and California variants. Please consult local AHJ to ensure code requirements are met.
6 of 8
Remote
Power-Up
Exit Cycle
Alarm Type
lock/unlock
Trigger
SW5
SW6
SW7
SW8
Sec
Status
Status
Off
0
Disables
Off
Unlock
Off
Off
External
Off
5
On
10
Enables
On
Lock
On
On
External
On
30
SW5
Sec
SW6
Status
SW7
Status
SW8
Off
0
Disables
Off
Unlock
Off
Off
External
Off
0
On
0
Enables
On
Unlock
On
On
External
On
0
SW5
SW6
SW7
SW8
Sec
Status
Status
Off
0
Disables
Off
Unlock
Off
Off
External
Off
0
On
0
Enables
On
Unlock
On
On
External
On
0
SW5
Sec
SW6
Status
SW7
Status
SW8
Off
0
Disables
Off
Unlock
Off
Off
External
Off
0
On
0
Enables
On
Unlock
On
On
External
On
0
Model Confirmation Display Codes
If auto relock is disabled, the 1200DE will show one of the following codes upon reset:
• -0 Standard 1200DE variant
Auto or
• -1 1200DE Chicago variant
Manual
Relock
• -2 1200DE California 15 second variant
• -3 1200DE California 30 second variant
SW9
Status
Status
Behavior of Delayed Egress
with Regional Settings
Voice
Off
Manual
California
Tone
On
Auto
Upon power up, lock goes into an alarm state and requires a manual reset. Nuisance delay
is settable to 0, 1, 2 or 3 seconds and the exit delay is fixed at 15 or 30 seconds. A manual
Status
SW9
Status
reset is required after a delayed egress event.
Chicago
Voice
Off
Manual
Upon power up, lock goes into an alarm state and requires a manual reset. Nuisance delay is
fixed at 1 second, the exit delay is fixed at 15 seconds, and the bypass delay is fixed at 0 seconds.
A manual reset is required after a delayed egress event.
Tone
On
Manual
1200DE Display Modes
SW9
Status
Status
Door armed and locked
15.
Voice
Off
Manual
Alarm countdown has ended,
00.
door is unlocked and alarm sounding
Tone
On
Manual
until reset.
Status
SW9
Status
Door unlocked and alarm is shunted
UN
(REX or Bypass)
Voice
Off
Manual
Door has been opened after
OP
REX, Bypass or Alarm.
Tone
On
Manual
Test Procedure / Troubleshooting
NOTE: Ensure wires are not pinched when cover is installed.
Error Codes
Sensor Switch Error
E1
If E1 error occurs during initial install, adjust sex bolt and retry activation.
Ensure sex bolt is flush or slightly below flush to the surface of the strike.
E2
Door Position Sensor Error
Device not in energy savings mode.
15.
Please check Door Position Sensor
and Sensor Switch
Flashing Dot
NOTE: Fire Alarm input: If fire brake not used, install provided jumper on the terminal block
if a dry normally closed contact from a fire alarm input OR smoke detector system is not connected.
*May not be applicable to specific Chicago and California variants. Please consult local AHJ to ensure code requirements are met.