1200DE Delayed Egress
Magnalock
Installation & Operating Instructions
Installation Hardware
Pack Components
1 Wrench 5mm HEX (1)
2 M8 x 35mm flat head socket
screw patched (1)
3 Flat rubber washer 16mm
x 8mm x 2mm (1)
4 Anti-Vandal Caps (4)
5 #10 x 1.5" Self-tapping flat
head patched (14)
6 Compression spring (1)
Specifications
• 1200 lbs. holding force
• Input Voltage: Dual voltage auto
sensing 12/24 VDC
• All Relay Outputs: 1A @ 30 VDC
• Tamper Switch Rating:
0.5A @ 30 VDC
• Maximum Current Draw:
– 825mA @ 12 VDC
– 490mA @ 24 VDC
• Energy Savings Mode Current Draw:
– 262mA @ 12VDC
– 165mA @ 24VDC
• Operating Temperature:
+32 to +122F [0 to +50C]
• Certifications:
– UL294
– UL10C
UL 294 Performance levels: Access Control Line Security Level 1,
Destructive Attack Level 1, Endurance Level IV, Standby Power Level 1.
IMPORTANT: UL 294 compliance requires that the locking device be powered
by a Listed (ALVY, FULA, FWAX, FWAX2, or APHV) Class 2 power supply.
Additional Model Numbers
• 1200DE-CA15S California-required 15s exit delay
• 1200DE-CA30S California-required 30s exit delay
• 1200DE-CH Chicago-required 15s exit delay,
1s nuisance delay, and 0s bypass time
®
7 Anti-Rotation pin 5mm
x 30mm (2)
8 M3 x 18mm flat head anti-
tamper screw (2)
9 2.54mm Jumper (2)
10 FPI Jumper (1)
11 Pair of Keys – A126
• Digital countdown LED display
• Door prop alarm
• Energy savings mode
• Field configurable settings include:
– Choice of English, French/English,
Spanish/English voice message
– Choice of voice and alarm tone or
alarm tone only
– Nuisance delay times 0, 1, 2,
or 3 seconds
– Bypass delay times 0, 5, 10,
or 30 seconds
– Door movement activation
– Auto or manual relock
• Integrated two function keyswitch
– Bypass (REX) and alarm reset
• Required sign included
73mm
1
6.8mm
4
0 1.2mm
/
5
6
38mm
8
18mm
13.8mm
10
35mm
2
0 16mm
/
0 8mm
/
3
2mm
0 1.2mm
/
19mm
30mm
7
0 5mm
/
6.5mm
9
5mm
1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALARM CONTROLS Magnalock 1200DE Delayed Egress and is the answer not in the manual?

Questions and answers

Summary of Contents for Assa Abloy ALARM CONTROLS Magnalock 1200DE Delayed Egress

  • Page 1 1200DE Delayed Egress Magnalock ® Installation & Operating Instructions Installation Hardware Pack Components 35mm 1 Wrench 5mm HEX (1) 7 Anti-Rotation pin 5mm x 30mm (2) 2 M8 x 35mm flat head socket screw patched (1) 8 M3 x 18mm flat head anti- tamper screw (2) 73mm 3 Flat rubber washer 16mm...
  • Page 2: Monitoring Outputs

    Wiring Instructions Delayed Egress Operation Delayed Egress Activation: Activation of the unlock cycle begins by causing door movement of at least 0.25”. Immediately after Reset Device activation, a short nuisance delay period is initiated. Nuisance delay time is field selectable* for 0, Optional 1, 2 or 3 seconds.
  • Page 3: Terminal Board Connections

    Terminal Board Connections Dipswitch Settings Overview NUISANCE DELAY (SW1, SW2 [ PWR ] [ FP ] [ RM TRIG [ RESET ] [ REX ] [ IBO ] [ LSS RLY ] [ ARM RLY ] [ DPS RLY ] [ ATS ] Nuisance delay is the configurable amount of time* (field configurable for 0, 1, 2 or 3 seconds) before the —...
  • Page 4 General DIP Switch Settings Model Confirmation Display Codes If auto relock is disabled, the 1200DE will show one of the following codes upon reset: • -0 Standard 1200DE variant Bypass Remote Auto or Nuisance Irrevocable Power-Up • -1 1200DE Chicago variant Code (Release) Exit Cycle...
  • Page 5: Mounting Options

    Printed in the U.S.A. techsupport.alarmcontrols@assaabloy.com Patent pending and/or patent www.assaabloydss.com/patents Copyright © 2023, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. alarmcontrols.com | 800-645-5538 All rights reserved. Reproduction in whole or in part without the express written permission of Hanchett Entry Systems, Inc. is prohibited. DOCD050_1...

Table of Contents