Problem
Device does not start
Low or lack of suction
Possible cause
Mains voltage is not present
Defective on/off switch
(
3)
Worn carbon brushes
Defective motor
Hose system (
13/14) or
jets (
18/19) blocked
Suction pipe (
12) assem-
bled incorrectly
Container (
6) open
Container (
6) full
Filter (
15/16/17) full or
clogged
Ball on filter basket (
incorrectly positioned (e.g.
due to jerky movements)
Fault correction
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Repair through customer service
Remove obstructions and block-
ages
Assemble suction pipe correctly
Close container
Empty container
Empty, clean or replace filter
21)
Switch off the equipment so the
ball drops then switch on again