Trouble Shooting - Parkside PNTS 1300 C3 Translation Of The Original Instructions

Wet & dry vacuum cleaner
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 40
GB
MT

Trouble shooting

Problem
Device does not start
Low or lack of suction
Float does not switch
the appliance off
Dust or dirt is blow
out of the device
48
Possible cause
Mains voltage is not present
Defective on/off switch
(
3)
Worn carbon brushes
Defective motor
Hose system (
13/14) or
jets (
18/20) blocked
Suction pipe (
12) assem-
bled incorrectly
Container (
6) open
Container (
6) full
Filter (
15/16/17) full or
clogged
Float in filter basket (
incorrectly positioned (e.g.
due to jerky movements)
Float in the filter basket
(
21) faulty
Float in the filter basket
(
21) does not move
Float in the filter basket
(
21) faulty
Filter (
15/16/17) is not
or not correctly assembled
Fault correction
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Repair through customer service
Remove obstructions and block-
ages
Assemble suction pipe correctly
Close container
Empty container
Empty, clean or replace filter
21)
Switch off the equipment so the
ball drops then switch on again
Repair by Customer Care
Release float
Repair by Customer Care
Use missing filters or check the
correct position of the filter

Advertisement