Installation Information - Air Techniques MOJAVE LT3M User And Installation Manual

Drystar monitor dry vacuum system
Table of Contents

Advertisement

INSTALLATION INFORMATION

Site Requirements
Electrical
Voltage Rating Volts AC
Voltage Minimum/Maximum
Wire Size AWG Minimum
Gauge
Minimum Circuit Breaker
Rating
Incoming Power
Remote (Low Voltage Wiring)
Plumbing
Exhaust Vent Pipe
Minimum Suction Line Pipe
Maximum Suction Line Pipe
(See note 2)
Riser Pipe
Vacuum Line Termination
Drain Hose
NOTES
1. Recommended for all new installations.
2. Use maximum internal diameter for the main line when preparing any new installation.
Recommended Space Requirement
Height
Width
Depth
Page 8
LT3M & LT5M Requirement
220 Volts, Single Phase AC, 60 Hz
198/242 Volts AC
Hard wire Connection
(unit is supplied with a 6 foot BX cable)
#18 AWG Wire Connection between the pump and
the Remote Switch Panel . Use of a high voltage switch not allowed .
LT3M & LT5M Requirement
1 ½ " PVC Sch . 40
1 " PVC Sch . 40 for LT3M
1 ½ " PVC Sch . 40 for LT3M
½ " PVC Sch . 40
1" Corrugated,
A full gravity drain is required .
LT3M & LT5M
20 in . (51 cm)
24 in . (61 cm)
16 .5 in . (42 cm)
#12 AWG
20A
1 ½ " PVC Sch . 40 for LT5M
2 " PVC Sch . 40 for LT5M
1 ½ " Spigot
Air Techniques, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mojave lt5m

Table of Contents