Important Warning - Nibe DRAZICE NADO 800/35v9 Operating And Installation Manual

Storage tanks

Advertisement

4 IMPORTANT WARNING

Connection of internal tank for hot water must comply with CSN 060830, i.e. on cold water inlet is necessary
to install a safety valve.
We recommend to start up the heating circle before commissioning and to clean possible dirts
caught in the filter and after this the system would be fully functional.
The appliance has to be mounted at a convenient place, it means that the appliance must be
easily available for potential necessary maintenance, repair or replacement, as the case may
be.
No stop fitting can be put between the security fitting of the heating circuit and the storage
tank!!!
Recommended operating pressure of hot water circle is 0.4 MPa. We recommend installing
return valve and an expansion vessel (min. 4 % of hot water in pipeline) on hot water outlet
to eliminate back pressure impacts.
The reservoir is possible to use only in compliance with conditions stated on performance plate
and with instructions for wiring. It is also necessary to observe terms for connection stipulated
by some local electrical and water companies as same as manual for assembling and operation
besides statutory accepted national regulations and standards.
Shut down the reservoir cold water intake if you are not using the reservoir for longer than
24 hours or if the object with the heater is without presence of any person.
- 6 -

Advertisement

loading

This manual is also suitable for:

Drazice nado 1000/35v9