Data Formatter; Primary/Alternate Data Formats - Honeywell HF680 Series User Manual

Hand-free area-imaging scanners
Hide thumbs Also See for HF680 Series:
Table of Contents

Advertisement

Data Formatter

When Data Formatter is turned Off, the barcode data is output to the host as read,
including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created and
saved. The following settings can be applied to your data format:
Default = Data Formatter On, Not Required, Keep Prefix/Suffix.

Primary/Alternate Data Formats

You can save up to four data formats, and switch between these formats. Your
primary data format is saved under 0. Your other three formats are saved under 1,
2, and 3. To set your device to use one of these formats, scan one of the barcodes
below.
HF680 Series User Guide
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that barcode is not
transmitted.
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Primary Data Format
Data Formatter Off
Data Format Required,
Keep Prefix/Suffix
65