WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can
result in death, fire, or electrical shock.
If codes permit and a separate ground wire
is used, it is recommended that a qualified
electrician determine that the ground path
is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are
not sure range is grounded.
Do Not have a fuse in the neutral or ground
circuit.
A 120-volt, 60-Hz, AC-only, 15-ampere, fused
electrical circuit is required. A time-delay fuse
or circuit breaker is recommended. It is recom-
mended that a separate circuit serving only this
range be provided.
Electronic ignition systems operate within wide
voltage limits, but proper grounding and polar-
ity are necessary. In addition to checking that
the outlet provides 120-volt power and is cor-
rectly grounded, the outlet must be checked by
a qualified electrician to see if it is wired with
correct polarity.
The wiring diagram is included in the literature
package. The wiring diagram can also be found
on the back of the range.

ELECTRICAL REQUIREMENTS

Note: The metal chassis of the range MUST be
grounded in order for the control panel to work.
If the metal chassis of the range is not grounded,
NO keypads will operate. Check with a quali-
fied electrician if you are in doubt as to whether
the metal chassis of range is grounded.
Recommended ground method
For personal safety, this range is equipped with
a power supply cord having a 3-prong ground
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong,
ground-type outlet, grounded in accordance
with the National Electrical Code, ANSI/NFPA
70—latest edition* or CSA Standard C22.1,
Canadian Electrical Code, Part 1,—latest edi-
tion** and all local codes and ordinances. If a
mating outlet is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded, 3-prong outlet in-
stalled by a qualified electrician.
3-Prong Ground-Type Outlet
3-Prong
Ground Plug
Ground
Prong
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts, 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575