4 Fix the thermistor harness using new tie straps.
Other refrigerant side thermistors
1 Pull the clip and install the thermistor in the specific thermistor holder. Make
sure the clip is in the correct position (blocking the thermistor).
a Clip
b Thermistor
c Thermistor holder
2 Route the thermistor harness towards the appropriate PCB.
3 Connect the thermistor connector to the appropriate PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
4 Fix the thermistor harness using new tie straps.
5 If applicable, install the insulation or putty around the thermistor.
Is the problem solved?
Yes
No
b
c
a
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.