Installation and operation manual Split system air conditioner Installation and operation manual FAA71BUV1B English Split system air conditioner FAA100BUV1B...
13.1.1 Refrigerant piping requirements........16 Daikin website (publicly accessible). 13.1.2 Refrigerant piping insulation ........16 ▪ The full set of latest technical data is available on the Daikin 13.2 Connecting the refrigerant piping ..........17 Business Portal (authentication required). 13.2.1 To connect the refrigerant piping to the indoor unit ..
4 17]) Electrical installation (see "14 Electrical Make sure installation, servicing, maintenance, repair and applied materials follow the instructions from Daikin and, in WARNING addition, comply with applicable legislation and are ▪ All wiring MUST be performed by an authorised performed by qualified persons only.
3 User safety instructions ▪ Batteries are marked with the following symbol: WARNING This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory This means that the batteries may NOT be mixed with unsorted household waste.
Page 6
3 User safety instructions WARNING CAUTION Before operating the unit, be sure the Do NOT insert fingers, rods or other installation has been carried out objects into the air inlet or outlet. When correctly by an installer. the fan is rotating at high speed, it will cause injury.
4 About the system WARNING About the system The appliance using R32 refrigerant WARNING shall be stored so as to prevent ▪ Do NOT modify, disassemble, remove, reinstall or mechanical damage and in a well- repair the unit yourself as incorrect dismantling or installation may cause an electric shock or fire.
5 User interface Outdoor units Cooling Heating RZQSG71~140 Outdoor –15~46°C DB –15~15.5°C WB temperature Indoor 14~28°C WB 10~27°C DB temperature Indoor humidity ≤80% — To avoid condensation and water dripping out of the unit. If the temperature or the humidity is beyond these conditions, safety devices may be put in action and the air conditioner may not Front panel operate.
6 Operation Icon Operation mode Direction Screen Cooling. In this mode, cooling will be activated as Fixed position. The indoor unit required by the setpoint, or by Setback operation. blows air in 1 of 5 fixed positions. Heating. In this mode, heating will be activated as required by the setpoint, or by Setback operation.
7 Maintenance and service NOTICE Maintenance and service ▪ Do NOT use gasoline, benzene, thinner polishing powder or liquid insecticide. Possible consequence: Precautions for maintenance and Discoloration and deformation. service ▪ Do NOT use water or air of 50°C or higher. Possible consequence: Discoloration and deformation.
8 Troubleshooting 6 Close the front panel slowly. Global warming potential (GWP) value: 675 Refrigerant type: R410A 7.2.3 To clean the air filter Global warming potential (GWP) value: 2087.5 NOTICE NOTICE Do NOT use water of 50°C or higher. Possible Applicable legislation on fluorinated greenhouse gases consequence: Discoloration and deformation.
9 Relocation If after checking all above items, it is impossible to fix the problem Malfunction Measure yourself, contact your installer and state the symptoms, the complete The operation switch does NOT function Turn OFF the power model name of the unit (with manufacturing number if possible) and properly.
12 Unit installation ▪ Wall insulation. When conditions in the wall exceed 30°C and a relative humidity of 80%, or when fresh air is inducted into the wall, then additional insulation is required (minimum 10 mm thickness, polyethylene foam). ▪ Wall strength. Check whether the wall is strong enough to support the weight of the unit.
12 Unit installation (mm) 1050 (mm) 1200 Pattern for installation with mounting plate for class 71 Pattern for installation with mounting plate for class 100 Recommended fixing spots Pocket for the pipe port cover Tabs for placing a spirit level Through-the-wall hole Ø80 mm Drain hose position Position for the tape measure at symbol "...
12 Unit installation 2 Shape the refrigerant pipes along the pipe path marking on the mounting plate. 3 Fix the electrical wiring and the refrigerant pipes together using vinyl tape (field supply). Cut off for side piping Cut off for bottom piping 1 Remove the front grille.
13 Piping installation Piping installation 13.1 Preparing refrigerant piping 13.1.1 Refrigerant piping requirements CAUTION Piping MUST be installed according to instructions given in Right-side piping installation" [ 4 16]. Only mechanical joints (e.g. "13 Piping Right-bottom piping Right-back piping braze+flare connections) that are compliant with the latest Remove the pipe port cover here for right side piping version of ISO14903 can be used.
14 Electrical installation 13.2 Connecting the refrigerant piping WARNING Use an all-pole disconnection type breaker with at least DANGER: RISK OF BURNING/SCALDING 3 mm between the contact point gaps that provide full disconnection under overvoltage category III. 13.2.1 To connect the refrigerant piping to the WARNING indoor unit If the supply cord is damaged, it MUST be replaced by the...
Page 18
14 Electrical installation 1 2 3 REMOTE TRANSMISSION FORCED CNTRL WIRING P1 P2 F1 F2 T1 T2 R-Ctrl D III-Net Interconnection wiring terminal User interface wiring terminal Power supply Interconnection wiring cable Residual current device User interface terminal wiring cable Outdoor unit Small tie wrap (accessory) Indoor unit...
NOTICE General commissioning checklist. Next commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin e(1) e(2) Business Portal (authentication required). The general commissioning checklist is complementary to Power supply the instructions in this chapter and can be used as a...
17 Configuration 16.2 To perform a test run If you want… Then — INFORMATION Fan operation Normal 11 (21) during thermostat For the test run procedure, see the reference guide or the Stop OFF (cooling/ service manual of the used user interface. heating operation) NOTICE During thermostat...
Daikin website (publicly accessible). Turn on the main power supply switch and set individual setting. ▪ The full set of latest technical data is available on the Daikin 5 Perform field setting for slave unit. Business Portal (authentication required).
Page 22
18 Technical data Symbol Meaning Symbol Meaning Connector (frame ground) Diode bridge, Insulated-gate bipolar transistor (IGBT) power Harness module H*P, LED*, V*L Pilot lamp, light emitting diode Wireless remote controller Light emitting diode (service Terminal monitor green) Terminal strip (block) HIGH VOLTAGE High voltage Electronic expansion valve coil...
Page 24
3P654518-1A 2021.03 Verantwortung für Energie und Umwelt...