  • Page 1 OPERATION MANUAL SPLIT SYSTEM Air Conditioners MODELS (Wall mounted type) FAA50BAVMA FAA60BAVMA FAA71BVMA FAA85BVMA FAA100BVMA...
  • Page 3 Thank you for purchasing this product unit. Carefully read this operation manual to ensure proper operation. After reading the manual, file it away for future reference. Furthermore, make certain that this operation manual is handed to a new user when he takes over the operation.
  • Page 4: Table Of Contents

    CONTENTS The appliance is not intended for use by unattended young children or persons who are 1. SAFETY PRECAUTIONS....... 1 incompetent to operate air conditioners. 2. WHAT TO DO BEFORE OPERATION... 4 It may result in injury or electric shocks. 3.
  • Page 5 WARNING Do not place flammable sprays near the unit as this can cause explosions. Do not use means to accelerate the defrosting Do not clean the air conditioner with organic process or to clean, other than those solvents such as paint thinner. recommended by the manufacturer.
  • Page 6 Consult your local dealer regarding Do not place water containers (flower vases, relocation and reinstallation of the air etc.) on the indoor unit, as this may result in conditioner. electric shocks or a fire. Improper installation work may result in leakage, Do not put flammable containers, such as electric shocks or a fire.
  • Page 7: What To Do Before Operation

    Do not remove the outdoor unit’s outlet side Ensure that the remote controller is not exposed grille. to direct sunlight. The grille protects against the unit’s high speed This will cause discoloration of the LCD display with fan, which may cause injury. resulting loss of readability.
  • Page 8: Operation Range

    If your installation has a customized control system, Remote controller (optional part) ask your local dealer for the operation that The remote controller may not be needed corresponds to your system. depending on the system configuration. Inlet air • Heat pump type This system provides COOLING, HEATING, Discharged air AUTOMATIC, PROGRAM DRY, and FAN...
  • Page 9: Installation Site

    Filled with much mineral oil such as cutting oil b. Where there is much salt such as a beach area System relocation c. Where sulfured gas exists such as a hot-spring • Consult your Daikin dealer about remodelling resort and relocation. d. Where there are considerable voltage fluctuations such as a factory or plant e.
  • Page 10  CHARACTERISTICS OF THE HEATING Regarding outside air temperature and OPERATION (HEATING OPERATION AND heating capacity AUTOMATIC HEATING OPERATION) • The heating capacity of the air conditioner declines as the outside air temperature falls. START OF OPERATION In such a case, use the air conditioner in •...
  • Page 11 MOVEMENT OF THE HORIZONTAL BLADE AIRFLOW DIRECTION ADJUST For the following conditions, micro computer controls the airflow direction so it may be different • There are 2 ways of adjusting the airflow direction. from the display. (When the operation stops, the horizontal blades •...
  • Page 12: Optimum Operation

    B. LEFT AND RIGHT DIRECTION • Turn off the power circuit breaker when it is not in use for a long period. When the power circuit Hold the tabs on edge louvers (horizontal airflow breaker is turned on, small amount of power is direction adjustment blades) down slightly and consumed even if the air conditioner is not in adjust left and right to match the room conditions...
  • Page 13 1. Open the front panel. CAUTION Place your fingers on the panel protrusions on • Do not wash the air conditioner with water. the left and right sides of the main unit and open It may cause electric shocks or a fire due to until the panel stops.
  • Page 14 NOTE 2. Remove the front panel. • Do not wash the air filter with water of 50°C or Push the axis on either side of the front panel higher. It may cause decolorization and towards the center of the main unit and remove deformation.
  • Page 15 HOW TO CLEAN AIR INLET, AIR OUTLET, HEATING OPERATION within 6 hours after the power is supplied to the air conditioner. OUTSIDE PANEL, AND REMOTE • Some models perform the following operation to CONTROLLER protect the devices. • Wipe them with a dry soft cloth. If the HEATING OPERATION is performed within •...
  • Page 16: Not Malfunction Of The Air Conditioner

    For comfortable use, do not turn off the 9. NOT MALFUNCTION OF THE power circuit breaker during seasonal use of AIR CONDITIONER the HEATING OPERATION. • The outdoor unit stops. The following symptoms do not indicate air This is because the indoor temperature has conditioner malfunction reached the set temperature.
  • Page 17 4. THE AIRFLOW DIRECTION IS DIFFERENT • When the air conditioner is changed over FROM THE SETTING, OR THE AIRFLOW to the HEATING OPERATION after the DIRECTION IS DIFFERENT FROM THE DEFROST OPERATION and in the DISPLAY ON THE REMOTE CONTROLLER DEFROST OPERATION.
  • Page 18: Trouble Shooting

    10. THE AIR CONDITIONER DOES NOT COOL 2. If the air conditioner stops after operating the EFFECTIVELY air conditioner. • The air conditioner is operating in the • Check if the air inlet or outlet of outdoor or PROGRAM DRY OPERATION. indoor unit is blocked by obstacles.
  • Page 19 • Check if the ventilation fan is in operation. • If a malfunction occurs, either one of the following messages will appear on the Basic screen on the • Check if direct sunlight enters the room (when wired remote controller during operation. cooling).
  • Page 20 The two-dimensional bar code is a manufacturing code. 3P427030-3R M15N111D (2110) HT...