Salicru EQUINOX2 3001-S User Manual page 58

Single-phase solar inverters connected to the grid
Table of Contents

Advertisement

Available languages

Available languages

e.
Connect the AC connector to the inverter's AC terminal;
a click indicates that the connection is in place, as shown
in Fig. 31:
Fig. 31. Connecting the AC connector to the inverter's AC terminal.
f.
Insert the relevant AC circuit breakers in between,
as shown in the table below:
Model
EQX2 2001-S
EQX2 3001-S
EQX2 3002-S
EQX2 3002-SX
EQX2 4002-S
EQX2 4002-SX
EQX2 5002-S
EQX2 5002-SX
EQX2 6002-S
EQX2 6002-SX
EQX2 8002-SX
EQX2 10002-SX
Tab. 10. AC circuit breakers
58
Thermal-
Over-
magnetic
Differen-
voltage
circuit
tial relay
protection
breaker
2P 16A
Curve C
2P 25A
30mA
2P 20A
Class A
Curve C
2P 32A
Curve C
40kA 230V
2P 40A
TT Type II
30mA
2P 40A
Class A
Curve C
2P 50A
2P 63A
Curve C
30mA
2P 63A
Class A
Curve C
g.
Connect the other end of the hose to the AC circuit breaker
in the junction box, downstream of the connection's IGA.
L
N
GND
Fig. 32. Electrical wiring diagram.
Previous
fuse. Max.
value
For the connection of equipment with 24h monitoring, see
(1/phase)
manual EL23300.
125 A gL
PIAs
ID
IGA
ID
Fus.
MCB
SPD
Inverter
SALICRU