Salicru EQUINOX2 3001-S User Manual page 56

Single-phase solar inverters connected to the grid
Table of Contents

Advertisement

Available languages

Available languages

b.
strings of different lengths):
If the installation does not have the solar panels on the
same plane, i.e., they receive different levels of irradiance,
either due to the shape of the roof or due to the different
inclination levels, or the lengths of the strings are not the
same, the connection must be made as follows:
Fig. 24. Connection of several solar fields and 2 MPPTs.
A different solar field is understood to be those that are
made up of panels from different manufacturers, lengths
and/or different powers.
56
Connection for installations with
fields of different power ratings
(panels with different direction and/or
Inverter
SPD
PV
PV
4.
Insert the positive and negative connectors into the respective
solar
DC input terminals of the inverter. If the terminals are properly
connected, they will make a clicking sound, as shown in Fig.
25 and Fig. 26:
Fig. 25. Connecting the DC input terminals of units with
Fus.
MCB
Fig. 26. Connecting the DC input terminals of units with
- Disconnect the AC circuit breaker from the grid side before
connecting the DC input terminals.
- The DC circuit breaker must be "OFF".
- Insulate the unused DC terminals with covers.
Fus.
MCB
SPD
1 MPPT.
2 MPPTs.