BFT THALIA P Installation Manual page 36

Hide thumbs Also See for THALIA P:
Table of Contents

Advertisement

Available languages

Available languages

TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Motor type
MOTOR TYPE
(Set the type of motor
connected to the
board).
Automatic Closing
TCA
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
ìIBL TCA
Block pulses during
IBL CLOSE
closing
Hammer during
RAM BLOW C. O P
opening
Hammer during
RAM BLOW C. C L
closing
Stop maintenance
BLOC PERSIST
Closing limit switch
PRESS SWC
pressure
42 -
THALIA P
INSTALLATION MANUAL
Cross out
Default
setting
used
0
1
2
3
4
5
0
6
7
8
9
10
0
0
Time
1
0
0
1
0
1
0
2
0
0
1
0
1
0
2
0
0
1
0
0
TCA
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
Motors not active
ELI 250 BT
PHOBOS N BT
IGEA BT
LUX BT
LUX G BT
SUB BT
KUSTOS BT A - PHOBOS BT A
GIUNO ULTRA BT A20 - GIUNO ULTRA BT A 50
VIRGO SMART BT A - 5 wires
VIRGO SMART BT A - 3 wires
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock
to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in
the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due
to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor inter-
preting this as an obstacle.
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the
mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing
limit switches to trip slightly earlier (Fig.G Ref.A).
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS

Advertisement

Table of Contents
loading

Table of Contents