BFT THALIA P Installation Manual page 31

Hide thumbs Also See for THALIA P:
Table of Contents

Advertisement

Available languages

Available languages

x2
***
0---
10--
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
autoset
LUX BT / LUX G BT
GIUNO ULTRA
l. s w adj
opm1
2
1
opm2
2
1
clm2
-
2
1
clm1
-
2
1
ersu
o
+/-
Control unit
software version
stat
vers
OK
bft . . .
+/-
- +
No total manoeuvres(in hundreds)
n. cycles
OK
0000
+/-
- +
No radio controldevices memorised
n. remotes
OK
00
+/-
- +
List of last 30 errors
OK
err
01. 3 3
02. 0 1
........
30. 1 5
+/-
0---
password
ACCESS MENUS Fig. 1
150-
1520
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as
verified photocell, Activation of the associated FAULT input  
PHOT
Activation of PHOT OP opening photocell input or, if
configured as active verified photocell only when opening,
PHOP
Activation of the associated FAULT input
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of
PHCL
the associated FAULT input
Activation of BAR safety edge input or, if configured as
verified safety edge, Activation of the associated FAULT input  
BAR
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE OPENING, or, if configured as verified safety edge active
baro
only while opening, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE CLOSING, or, if configured as verified safety edge active
barc
only while closing, Activation of the associated FAULT input
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in order
SET
to acquire the torque required for movement.
WARNING! Obstacle detection not active
Manual movement
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
2
1
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
-
Opening safety edge test failed
ER07
2
1
Closing safety edge test failed
ER08
Board hardware test error
ER1x*
Encoder error
ER2x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
ER73
Error in setting the SAFE inputs
ERf3
Solenoid lock output overload
ERF9
Error during limit switch adjustment
Ersw
Only for Lux BT e Lux-G BT
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
ok
35. 4 0
DESCRIPTION
1520
prg
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
C
= SWC2 motor 2 closing limit
switch input activated
O
= SWO2 motor 2 opening limit
switch input activated
C
= SWC1 motor 1 closing limit
switch input activated
O
= SWO1 motor 1 opening limit
switch input activated
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
- Motor power or encoder signal cables inverted/disconnected.
- Actuator movement is too slow or stopped with respect
to programmed operation.
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory
devices and/or expansion boards
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters
and Logics)
Pressing OK, the board will keep on working with D-
track as a default.
An autoset is required
Check the setting of the SAFE inputs is correct
-Check lock connections
- Unsuitable lock
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both the opening
and closing limit switches.
- Caution: the last centimetre of the piston's stroke,
during either opening or closing, cannot be used.
 
THALIA P -
37