SMA Solar Technology AG
13.2 Sunny Multigate
AC Input
Maximum number of connected micro inverters
Minimum number of connected micro inverters
Maximum input current
AC Output
Rated power at 230 V, 50 Hz
Rated grid voltage
Nominal AC voltage
AC voltage range
Nominal AC current at 220 V
Nominal AC current at 230 V
Nominal AC current at 240 V
Maximum output current
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power
Rated power frequency
AC power frequency
Operating range at AC power frequency 50 Hz
Operating range at AC power frequency 60 Hz
Power factor at rated power
Feed-in phases
Connection phases
Overvoltage category as per IEC 60664-1
Protective Devices
Overvoltage protection
Maximum permissible fuse protection
Installation Manual
12
1
12 A
2,760 W
230 V
220 V / 230 V / 240 V
184 V to 270 V
12 A
12 A
11.5 A
12 A
≤ 3%
50 Hz
50 Hz / 60 Hz
45.5 Hz to 63 Hz
45.5 Hz to 63 Hz
1
1
1
III
Varistors
16 A
SMG-SB240-IA-en-11
13 Technical Data
69