SMA Solar Technology AG
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power
Maximum residual output current
Rated power frequency
AC power frequency
Operating range at AC power frequency 50 Hz
Operating range at AC power frequency 60 Hz
Power factor at rated power
Feed-in phases
Connection phases
Overvoltage category with Sunny Multigate as
per IEC 60664-1
Protective Devices
DC reverse polarity protection
Grid monitoring
AC short-circuit current capability
Ground-fault monitoring
Galvanic isolation
General Data
Width x height x depth, without connection area
Width x height x depth, with connection area
Weight
Operating temperature range
Maximum permissible value for relative humidity,
non-condensing
Maximum operating altitude above MSL
Noise emission, typical
Power loss in night mode
Topology
Installation Manual
≤ 3%
241 A
50 Hz
50 Hz / 60 Hz
45.5 Hz to 63 Hz
45.5 Hz to 63 Hz
1
1
1
III
Short-circuit diode
SMA Grid Guard 5
Available
Insulation monitoring
Available
188 mm x 199 mm x 43 mm
188 mm x 218 mm x 43 mm
1.3 kg
− 40°C to +65°C
100%
3,000 m
≤ 38 dB(A)
< 0.03 W
HF transformer
SMG-SB240-IA-en-11
13 Technical Data