Troubleshooting

10. Troubleshooting
The following table lists some problems that may be
encountered, with possible causes and solutions.
If a problem persists after reading through the Troubleshooting
section, contact the local dealer, distributor or Wallenstein
Equipment. Have the machine serial number ready.
Problem
Engine is difficult to start or performance
is reduced.
Cylinder rod moves slowly or does not
move. Screeching or hissing noise.
Control handle does not go to neutral
after rod is fully retracted.
Control handle goes to neutral before rod
is fully retracted.
Control handle does not go to neutral
when released.
Cylinder stops on contact with wood.
Wedge or push block jumps.
Leaking hydraulic hose.
Leaking cylinder.
Cause
Engine fuel. Not all fuel is the same.
No hydraulic fluid pressure.
Wood jammed around wedge.
Low engine speed.
Valve detent set too tight.
Hydraulic fluid too cold.
Hydraulic fluid is contaminated.
Detent is set too loose.
Control may be damaged.
Second stage on pump is not functioning.
Wedge or push block frame is jamming.
Hose is worn or damaged.
Seals are worn.
36
Solution
Change the fuel provider or brand.
Fluid filter is plugged. Change filter.
Low hydraulic fluid level. Add fluid.
System relief pressure setting too low. Call
technician.
Shut machine off and safely remove wood.
Check throttle is set to maximum. Check that
choke is off.
Adjustment required to detent on valve.
Allow machine to warm up.
Change hydraulic fluid and filter.
Adjustment required to detent on valve.
Control may need service or be replaced. Call
technician.
Pump may need to be serviced or replaced. Call
technician.
Lubricate slider wear plates.
Replace hose.
Seal replacement may be required. Call
technician.