Capacitance
RANGE
60.00nF, 600.0nF, 6.000F
60.00F,600.0uF
2000F
Accuracies with film capacitor or better
1)
Temperature Coefficient: 0.25 x (specified
2)
accuracy)/ C @(0C -- 18C or 28C --
40C)
Diode Tester
RANGE
1.000V
Test Current: 0.56mA typically
Open Circuit Voltage: < 1.8VDC typically
DCA Current (Clamp on)
RANGE
200.0A
0~500A
500~2000A
Induced error from adjacent current-
1)
carrying conductor: <0.1A/A
Specified with Relative Zero
2)
applied to offset the non-zero residual
readings, if any
Temperature (Models 198PV & 197 only)
RANGE
-50
C ~ 1000
C
o
o
-58
F ~ 1832
F
o
o
K-type thermocouple range & accuracy not
included
Accuracy
1)
2.0%+5d
3.5%+5d
2)
4.0%+5d
2)
Accuracy
1.0% + 3d
Accuracy
1) 2)
2.0%+5d
2.0%+5d
3.0%+5d
mode
Accuracy
0.3% +4d
0.3% + 6d
ACA Current (Clamp on)
RANGE
50Hz ~ 60Hz
200.0A
0~500A
500~2000A
40Hz ~ 50Hz & 60Hz ~ 400Hz
200.0A
0~500A
500~1000A
1000~2000A
True RMS Crest Factor (Models 198PV &
197 only):
< 1.4 : 1 at full scale & < 2.8: 1 at half
scale
Induced error from adjacent current-
1)
carrying conductor: < 0.1A/A
DC+ACA Current (Clamp on)
(Models 198PV & 197 only)
RANGE
DC, 50Hz ~ 60Hz
200.0A, 2000A
40Hz ~ 50Hz & 60Hz ~ 400Hz
200.0A
0~1000A
1000~2000A
True RMS Crest Factor:
< 1.4 : 1 at full scale & < 2.8 : 1 at half
scale
Induced error from adjacent current-
1)
carrying conductor: < 0.1A/A
Specified with Relative Zero
2)
applied to offset the non-zero residual
readings if any
17
Accuracy
1)
2.0%+5d
2.5%+5d
3.0%+5d
2.5%+5d
3.0%+5d
3.5%+5d
unspecified
Accuracy
1) 2)
3.0%+8d
3.5%+8d
3.5%+8d
unspecified
mode