When to adjust the processing parameters
You may want to adjust the processing parameters
• when environmental conditions change, e.g. relative humidity or room tempera-
ture,
• when other chemicals will be used,
• when another type of film will be used.
Changing some of the parameters can have a negative effect on the image
quality. Always consult your local service organization.
Overview of recommended settings
The table below lists the recommendations for optimal processing stability,
depending on your specific workload.
more than 5 m² film/day
daily use
irregular use
400 ml/m²
Standby developer and fixer replenishment - jog cycle (*)
more than 5 m² film/day
daily use
irregular use
OFF
more than 5 m² film/day
daily use
irregular use
OFF
(*) The default setting is AUTO: the developer and fixer jog cycle is set automati-
cally ON if the daily film consumption is less than 3 m². It is set automatically
OFF if the daily film consumption is more than 3 m².
1280C GB 20001204
Developer replenishment rate
3 to 5 m² film/day
daily use
400 ml/m²
600 ml/m²
3 to 5 m² film/day
daily use
OFF
OFF
Start-up replenishment function
3 to 5 m² film/day
daily use
ON
OFF
less than 3 m² film/day
irregular use
daily use
600 ml/m²
600 ml/m²
less than 3 m² film/day
irregular use
daily use
OFF
less than 3 m² film/day
irregular use
daily use
ON
OFF
irregular use
600 ml/m²
irregular use
ON
ON
irregular use
ON