Conair 100 User Manual page 54

D carousel dryer - dc-1 models 15, 25, 50, 75, and 100 with dc-1 controls
Table of Contents

Advertisement

4 - 1 4
l O p e r a t i o n
C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
Screen 28-43 require access
code 755.
SCREEN 34 (Test Mode Screen)
H
off
SCREEN 35 (Test Mode Screen)
off
H
SCREEN 36 (Test Mode Screen)
H
off
SCREEN 37 (Test Mode Screen)
off
H
SCREEN 38 (Test Mode Screen)
off
H
F u n c t i o n
This is the Test Mode screen for the isola-
tion contactor. By pressing the + or - keys,
7
the setting can be changed. When set to
"On", the isolation contactor output will be
turned on for 3 sec. and then shut off auto-
matically.
This is the Test Mode screen for the alarm
output (horn and or red light). By pressing
8
the + or - keys, the setting can be changed.
When set to "On", the alarm output will be
turned on for 3 sec. and then shut off auto-
matically.
This is the Test Mode screen for the pre-
cooler flow control valve. By pressing the
9
+ or - keys the setting can be changed.
When set to "On" the precooler flow con-
trol valve output will be turned on for 3
sec and then shut off automatically.
This is the Test Mode screen for the after-
cooler flow control valve. By pressing the
+ or - keys, the setting can be changed.
10
When set to "On", the aftercooler flow
control valve output will be turned on for
3 sec. and then shut off automatically.
This screen is not used in the current pro-
gram.
11
Note: The alarm light on the membrane
switch will not come on. If the optional
alarm horn or red light is not installed,
nothing will happen.
Note: If the optional precooler flow control
valve is not installed, nothing will happen.
Note: If the optional aftercooler flow control
valve is not installed, nothing will happen.
( c o n t i n u e d )