C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
Screen 28-43 require access
code 755.
SCREEN 29 (Test Mode Screen)
2
H
off
SCREEN 30 (Test Mode Screen)
off
3
H
SCREEN 31 (Test Mode Screen)
4
H
off
SCREEN 32 (Test Mode Screen)
off
5
H
SCREEN 33 (Test Mode Screen)
off
6
H
F u n c t i o n
This is the Test Mode screen for the
process heater. By pressing the + or -
keys, the setting can be changed. When
set to "On", the process heater output will
be turned on for 3 sec. and then shut off
automatically.
Note: The isolation contactor will not be
pulled in so no electricity will go the heater.
The solid state relay contacts should close.
This is the Test Mode screen for the regen-
eration blower. By pressing the + or -
keys, the setting can be changed. When
set to "On", the regeneration blower output
will be turned on for 3 sec. and then shut
off automatically.
This is the Test Mode screen for the regen-
eration heater. By pressing the + or - keys,
the setting can be changed. When set to
"On", the regeneration heater output will
be turned on for 3 sec. and then shut off
automatically.
Note: The isolation contactor will not be
pulled in so no electricity will go the heater.
The solid state relay contacts should close.
This is the Test Mode screen for the bed
drive motor. By pressing the + or - keys,
the setting can be changed. When set to
"On", the bed drive motor output will be
turned on until the limit switch makes the
next valley, and then shut off automatically.
This Test Mode screen is not used in the
current program.
( c o n t i n u e d )
(continued)
O p e r a t i o n l
4 - 1 3