  Summary of Contents for Conair 10

  • Page 1 Positive Displacement Pump Models PD3, 5, 7.5, 10, 15 and 25 Installation Maintenance Operation Troubleshooting Instant Access Parts and Service (800) 458-1960 (814) 437-6861 www.conairnet.com The Conair Group, Inc. One Conair Drive Pittsburgh, PA 15202 Phone: (412) 312-6000 Fax: (412)-312-6320...
  • Page 2 IMB036/0898 Serial number(s): Model number(s): DISCLAIMER: The Conair Group, Inc., shall not be liable for errors contained in this User Guide or for incidental, consequential dam- ages in connection with the furnishing, performance or use of this information. Conair makes no warranty of any kind with regard to this information, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3: Table Of Contents

    NTRODUCTION ATTENTION: Read this first so no one gets hurt ..1 Description ........2 Optional Sound Enclosures .
  • Page 4: Attention: Read This First So No One Gets Hurt

    ATTENTION: EAD THIS SO NO ONE GETS HURT We design equipment with the user’s safety in mind. You can avoid the potential hazards identified on this machine by following the procedures outlined below and elsewhere in the User Guide. WARNING: Improper installation, operation or servicing may result in equipment damage or personal injury.
  • Page 5: Description

    Conair positive displacement vacuum pumps are designed for long distance, high-volume material conveying applications. Each model employs a powerful, rotating lobe-type blower, protected by a vacuum relief valve (factory-set to 12 in. Hg) and belt driven by a three-phase motor with magnetic starter and overload protection.
  • Page 6: Specifications

    Specifications not listed below are the same as those listed above. All Sound Enclosures include a cooling fan 115 VAC @ 2 amps. MODEL Performance characteristics Average sound level (dbA) @ 8", 10" and 12" Hg Enclosure Construction Allowance Space for service access / in Dimensions / in.
  • Page 7: Installing The Pump

    Hg. Excessive vacuum will reduce the life of the pump and can destroy it. For special applications requiring a higher vacuum level, consult Conair service. If the vacuum relief valve is adjusted by any person other than a facto- ry service representative, the warranty is voided.
  • Page 8: Maintenance

    Every 1500 hours of operation Change the oil. The vacuum pump has been filled with the proper oil and tested by Conair before shipment. Even so, this oil should be changed periodically. Use SAE 40 regular or an equivalent oil.
  • Page 9 Conair has made the largest investment in customer support in the plastics industry. Our service experts are available to help with any problem you might have installing and operating your equipment. Your Conair sales representative also can help analyze the nature of your problem, assuring that it did not result from misapplication or improper use.
  • Page 10 Returns must be prepaid. Purchaser must notify Conair in writing of any claim and pro- vide a customer receipt and other evidence that a claim is being made.