D carousel dryer - dc-1 models 15, 25, 50, 75, and 100 with dc-1 controls
Table of Contents

Advertisement

When config-
ured as a central
dryer, the MDC
option is not
available.
Central
Dryer model
Hopper selection*
Performance characteristics
Air flow
{SCFM}†
Air flow {ACFM @250° }
Drying temperature ‡
Dew point
Maximum conveying distance ft {m}
with long-distance option
Dimensions inches {cm}
A - Height to top of hopper
B - Total height
C - Width
D - Depth
Weight lb {kg}
Shipping
Voltages§ Total amps
208V/3 phase/60 Hz
240V/3 phase/60 Hz
400V/3 phase/50 Hz
480V/3 phase/60 Hz
575V/3 phase/60 Hz
Total kilowatts kW
Water requirements {for optional aftercooler}
Recommended temperature **
Water flow gpm {liters/min.}
SPECIFICATION NOTES:
* Consult Conair about other available hopper selections.
† SCFM stands for standard cubic feet per minute, referenced to a pre-specified pressure, temperature and relative humidity. In most cases, SCFM is referenced to
14.7 PSIA 68° F and 0% relative humidity. ACFM stands for actual cubic feet per minute, and must be supplied with a temperature reference, due to the change in
air density with temperature. Because dryers operate at a relatively low pressure the effects on air density are negligible.
‡ When drying below 150° F a precooler is required. When drying above 250° F an aftercooler and insulated drying hose is required.
§ Dryers running at 50 HZ will have 17% less airflow, and a 17% reduction in material throughput.
** Temperatures above or below the recommended levels may affect dryer performance. Tower, chiller or municipal water sources can be used.
Throughputs will vary by type of material. Consult Conair for throughput information.
Specifications may change without notice. Check with a Conair representative for the most current information.
S p e c i f i c a t i o n s : M D C
MDC15 and MDC25
CH10-1
CH10-1.5
CH14-2
12
20
16
27
All models 100° -375° F {38°-191° C} with options ‡
15 {4.57} vertical; 50 {15.24} horizontal
56 {142.2}
67 {170.2} 58 {147.3} 69 {175.3} 80 {203.2} 66 {167.6} 78 {198.1}
100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 105 {266.7}
48 {121.9}
48 {121.9} 48 {121.9} 48 {121.9} 48 {121.9} 54 {137.2} 54 {137.2}
30 {76.2}
30 {76.2}
30 {76.2}
590 {268}
600 {272} 650 {29.5}
STD LONG DIST.STDLONG DIST. STANDARD
8.6
11
9.5
11.9
12.1
7.7 10.1
8.5
10.9
10.8
4.3
5.4
4.7
5.8
3.8
4.6
4.2
5.0
3.1
4.5
3.4
4.8
2.8
3.4
3.1
3.7
MDC50
CH14-3
CH14-4
35
47
All models -40° F {-40° C}
8 {2.44} vertical; 6 {1.83} horizontal
30{76.2}
30 {76.2}
660 {299}
670 {304}
LONG DIST.
14.5
13.2
6.2
7.3
5.4
6.2
4.4
5.8
4.0
4.6
70°-90° F {21°-32° C}
3 {11.36} / 1/2 inch NPT female fittings
( c o n t i n u e d )
MDC75
CH18-4
CH18-6
CH24-8
50
67
76 {193.0} 89 {226.1} 105 {266.7}
54 {137.2} 54 {137.2} 54 {137.2}
36 {91.4}
36 {91.4}
36 {91.4}
785 {356}
805 {365}
1025 {465} 1055 {478} 1075 {488}
STANDARD
LONG DIST.
STANDARD
20.2
22.6
17.8
20.2
10.3
11.4
8.9
9.7
7.3
8.7
6.7
7.3
MDC100
CH24-12
CH24-15
80
107
36 {91.4}
36 {91.4}
LONG DIST.
NA
NA
27.3
29.7
14.8
15.9
12.7
13.5
10.4
11.8
9.6
10.2
A p p e n d i x l
G - 5