Conair 100 User Manual page 49

D carousel dryer - dc-1 models 15, 25, 50, 75, and 100 with dc-1 controls
Table of Contents

Advertisement

C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
Screens 15-27 require access
code 754.
SCREEN 15 (Set up Screen)
10
C01
C
SCREEN 16 (Set up Screen)
C02
C
400
SCREEN 17 (Set up Screen)
C03
C
off
SCREEN 18 (Set up Screen)
425
C04
C
SCREEN 19 (Set up Screen)
off
C05
C
F u n c t i o n
This is the process deviation temperature
screen. The range is 5 - 20
-6.7
. This is the deviation temperature
°C)
band around the set point. If the dryer
goes outside this band, the dryer will dis-
play a passive alarm (P1).
This is the process high temperature
screen. This is the high temperature limit.
If the process temperature reaches this set-
point, the dryer will shutdown on alarm
A1.
This is the process heater autotune screen.
The autotune function can be turned on by
pressing the + key. Once the + key is
pressed, the screen will show On and then
start the autotune process. This may take a
minute or so to complete. When finished,
the display will read "don". The new PID
values are automatically saved.
This is a regeneration temperature screen.
This is the regeneration heater autotune
screen. The autotune function can be
turned on by pressing the + key. Once the
+ key is pressed, the screen will show On
and then start the autotune process. This
may take a minute or so to complete.
When finished the display will read "don".
The new PID values are automatically
saved.
( c o n t i n u e d )
F (-15.0 -
°
Central
When supplied for
central drying appli-
cations, these func-
tions are not available.
O p e r a t i o n l
4 - 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

15507525D15D25 ... Show all

Table of Contents