Conair 100 User Manual page 110

D carousel dryer - dc-1 models 15, 25, 50, 75, and 100 with dc-1 controls
Table of Contents

Advertisement

Note: See instructions sent
along with your upgrade kit
to enable this option.
Represents 15, 25, and 50 models
F - 1
l A p p e n d i x
I n s t a l l i n g t h e D e w Po i n t S e n s o r
( O p t i o n a l )
The dew point sensor can be mounted to the inside bottom right corner of the
dryer back panel.
1
Peal the tape from the dew point sensor block and place it in the bottom
right side of the back panel as shown.
3
Route the hose near the bottom of the sensor block to the 1/8" (3.18 mm)
NPY hose fitting on the inlet of the process blower. The inlet is the tube
toward the center of the dryer.
4
The dew point sensor comes with a plug wire attached. Reference the
wiring diagram to attach this wire to the proper points on the board.
2
Route the hose near the top
of the block to the fitting
near the top of the process
heater tube (D 15, D 25,
and D 50) or the fitting
near the bottom of the
process heater tube
(D 75 and D 100).
Represents 75 and 100 models

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

15507525D15D25 ... Show all

Table of Contents