Installer Setup
Fan Off Delay in Seconds
(setup step 21)
This feature allows the user to increase the
cooling or electric strip heating efficiency of the
system. The thermostat may be programmed to
continue running the fan after a call for cooling
or electric strip heating has been satisfied. This
delay can be set for 0, 30, 60, 90, or 120 seconds.
If set to 0, the fan will not run after a call for
cooling or electric strip heating has
been satisfied.
Fahrenheit or Celsius
(setup step 22)
This feature allows the thermostat to display
temperature in Fahrenheit or Celsius.
Comfort Recovery
(setup step 23)
With Comfort Recovery on, the thermostat will attempt to reach the
Morning setpoint temperature at the exact time programmed into
the thermostat. Comfort Recovery, only works when the thermostat
enters the Morning period from the Night Period. For example, if the
Night Period is set for 11pm at 65°F heating and 85°F cooling, and the
Morning Period is set for 6am at 72°F heating and 75°F cooling, the
thermostat will turn the system on before 6am in an effort to bring the
temperature to its correct setting at exactly 6am. The thermostat learns
from experience, how early to turn on, so please allow 4-8 days after a
program change or after initial installation to give
Comfort Recovery time to adjust. If used with a
heat pump, electric strip heat will be disabled
while Comfort Recovery is active.