Pneumatic arm single monitor desk mount with usb (8 pages)
Summary of Contents for Vivo STAND-V101Q
Page 1
Pneumatic Arm Single Ultrawide Monitor Desk Mount Instruction Manual SKU: STAND-V101Q Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product. https://vivo-us.com/products/stand-v101q GET IN TOUCH | Monday-Friday from 7:00am-7:00pm CST help@vivo-us.com...
Page 2
WARNING! If you do not understand these directions, or if you have any doubts about the safety of the installation, please call a qualified technician. Check carefully to make sure there are no missing or defective parts. Improper installation may cause damage or serious injury. Do not use this product for any purpose that is not explicitly specified in this manual.
Page 3
DO NOT EXCEED WEIGHT CAPACITY. 2.2-30.9lbs Failure to do so may result in serious injury. (1-14kg) PER ARM ASSEMBLY STEPS STEP 1 (Option A) Clamp Installation Secure Upper Clamp (E) to the underside of Base (D) using M6x10mm Flathead Screws (S-B) and 4mm Allen Wrench (T-B).
Page 4
STEP 1 (Option B) Grommet Installation Insert Carriage Bolt (S-A) into Grommet Plate (H) and secure to underside of Base (D) using M6x10mm Flathead Screws (S-B) and 4mm Allen Wrench (T-B). Peel back adhesive backing and apply Pads (K) to underside of Base (D). Place base assembly over grommet hole in desktop and place Support Plate (I) and Knob (J) on the end of Carriage Bolt (S-A).
Page 5
STEP 2 Place Lower Arm (B) onto Base (D) and secure by tightening set screw with 3mm Allen Wrench (T-A). Install Upper Arm (A) on Lower Arm (B) and tighten set screw with 3mm Allen Wrench (T-A) to secure. STEP 3 Secure VESA Plates (C) to back of monitors using appropriate Screws (M-A thru M-D), M6 Washers (M-E), and 6mm Allen Wrench (T-C).
Page 6
STEP 4 Place monitor with VESA Plate (C) onto Upper Arm (A) and secure with M6x12mm Thumbscrew (S-C). STEP 5 While holding Upper Arm (A) in the horizontal position, adjust the gas spring tension using 6mm Allen Wrench (T-C). Adjusting Tension Decrease Strength - If the arm raises up, turn the adjustment screws clockwise until it holds the...
Page 7
Cable Management Covers Lower Arm (B): Upper Arm (A): 1. Slide cover forward to remove. 1. Pull tabs outward on lower portion of cover. 2. Place cables in cover. 2. Pull upper tabs outward to fully remove cover. 3. Connect inner tabs to clips on Lower 3.
Page 8
- 38% within < 30m - 61% within < 1hr - 83% within < 2hr - 92% within < 3hr FOR MORE VIVO PRODUCTS, CHECK OUT OUR WEBSITE AT: www.vivo-us.com FOR MORE VIVO PRODUCTS, CHECK OUT OUR WEBSITE AT: www.vivo-us.com...
Need help?
Do you have a question about the STAND-V101Q and is the answer not in the manual?
Questions and answers