EventControl

Name
EventSelector
EventNotification [EventSelector]
EventTestData
EventExposureStartData
EventExposureEndData
EventFrameTriggerData
EventFrameStartData
EventFrameEndData
EventLine0RisingEdgeData
EventLine0FallingEdgeData
EventLine2RisingEdgeData
EventLine2FallingEdgeData
EventBlockDiscardData
EventActionLateData
11.11

UserSetControl

Name
UserSetSelector
UserSetLoad [UserSetSelector]
UseSetSave [UserSetSelector]
UserSetDefault
STC-MBS312POE / STC-MCS312POE
Product Specifications and User's Guide
Description
Selects which Event to signal to the host application.
Activate or deactivate the notification to the host application of the
occurrence of the selected Event.
Category that contains all the data features related to the Event Test
generated using the Test Event Generate command.
Category that contains all the data features related to the Exposure
Start Event.
Category that contains all the data features related to the Exposure
End Event.
Category that contains all the data features related to the Frame
Trigger Event.
Category that contains all the data features related to the Frame Start
Event.
Category that contains all the data features related to the Frame End
Event.
Category that contains all the data features related to the Line0 Rising
Edge Event.
Category that contains all the data features related to the Line0 Falling
Edge Event.
Category that contains all the data features related to the Line2 Rising
Edge Event.
Category that contains all the data features related to the Line2 Falling
Edge Event.
Category that contains all the data features related to the Block
Discard Event.
Category that contains all the data features related to the Action Late
Event.
Description
Selects the feature User Set to load, save or configure.
Loads the User Set specified by User Set Selector to the device and
makes it active.
Save the User Set specified by User Set Selector to the non-volatile
memory of the device.
Selects the feature User Set to load and make active by default when
the device is reset.