- All Other Markets:
Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
(*) NOTE:
 Measure burner operating pressure at manifold test point with both burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
apart from when converting between gasses, if required.
 TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas adjustable
gas regulator supplied.
 Refer to 'Gas Conversion and Specifications' section of this manual for further details.
Gas supply connection point is located 25mm in from the rear of the appliance, 130mm from the right
hand side and is entered from beneath appliance.
Connection is ½ BSP male.
31.5 MJ/hr
1.13 - 3.40 kPa
1.0 kPa
1
/
" BSP Male
2
31.5 MJ/hr
2.75 - 4.50 kPa
2.55 kPa
1
/
" BSP Male
2
5
40 MJ/hr
0.76 - 1.50 kPa
0.63 kPa
31.5 MJ/hr
2.75 - 4.50 kPa
2.55 kPa