Page 3
SN(B)8200G GAS SALAMANDER (Branding Plate Optional). SN(B)8200GB GAS SALAMANDER (With Branding Plate). Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions Internal Dimensions Cooking Area Weight Installation Requirements Unpacking Location Clearances Wall Mounting (to non combustible wall only) Gas Connection Commissioning Operation Guide...
Page 4
We are confident that you will be delighted with your Waldorf Gas Salamander, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Salamander, there are two important things you can do.
Page 5
Branding Plates are fitted onto standard wire rack allowing ease of change as required between menus. Waldorf Salamanders come as standard with a trough tray incorporating a front grease trough for direct collection of cooking grease from Branding Plate operation.
Page 8
Width 685mm. Height 230mm (at front). Depth 330mm. Rack 610mm x 310mm. Branding Plate (Accessory) 610mm x 310mm. 41kg (without Branding Plate or Racking System).
Page 9
Installation shall comply with local electrical, gas, health and safety requirements. Waldorf Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas and fire safety.
Page 10
NOTE: Only non-combustible materials can be used in close proximity to this appliance. Left / Right Hand side 100mm 25mm (*) Rear 50mm 30mm (**) We recommend a clearance of 100mm on either side of appliance to allow access to side panels for servicing purposes.
Page 11
Fix wall mounting bracket to wall with six screws, in a position where the top of bracket is level and at least 945mm (38”) above any surface beneath unit. This will ensure that bottom of Salamander is at least 600mm (24”) above any surface. Fit two black plastic spacers to top rear corners of unit.
Page 12
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON. Waldorf Salamanders do not require an electrical connection, as they function totally on gas supply only. It is essential that gas supply is correct for Salamander to be installed and that adequate supply pressure and volume are available.
Before leaving the new installation; a. Check the following functions in accordance with operating instructions specified in Operation section of this manual. Light the Main Burners. Check the Low Fire burner operation. Check the High Fire burner operation. ...
Waldorf Salamanders have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce the life of the salamander and produce a poor quality product. To use this salamander correctly please read the following sections carefully:- ...
Page 15
Check gas supply is turned On. Depress gas control knob and rotate anti-clockwise to HIGH position. a. Non UK Models (Piezo Ignition):- With gas control knob depressed, press piezo ignition button to ignite main burner. b. UK Models (Manual Ignition):- Manually light Main Burner, holding Gas Control Knob depressed for approx.
Page 16
To achieve the best results, cleaning must be thorough and all controls and mechanical parts checked and adjusted periodically by a competent serviceman. If any small faults occur, have them attended to promptly. Don't wait until they cause a complete breakdown. ...
Page 17
NOTE: All maintenance operations should only be carried out by a qualified service person. To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person. If any small faults occur, have them attended to promptly.
Page 18
This section provides an easy reference guide to the more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Page 19
NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. For all the following conversion instructions, the side access panels have to be removed (Remove two screws at bottom of each side panel). ...
Page 20
NOTE, Pin rotated - NAT Gas / LPG / Butane Only. for Natural Gas. NOTE: Gas regulator supplied convertible between Natural Gas and LP Gas, but it’s outlet NOTE, Pin rotated pressure is fixed ex-factory and for LPG. is NOT to be adjusted. - Town Gas Only.
Page 21
- Australia: Main Burner Injectors Ø 1.85mm Ø 1.15mm Size Ø 1.00mm Ø 1.00mm Fire Adjustment 2 turns out (c.c.w.) ½ turn out (c.c.w.) Supply Pressure 1.13 - 3.4 kPa 2.75 - 4.5 kPa Burner Operating Pressure (*) 1.0 kPa 2.55 kPa Gas Regulator Cap Screw - New Zealand:...
Replacement Parts List IMPORTANT: When ordering spare parts, please quote part number and description as listed below. If part required is not listed below, request part by description and quote model number and serial number which is shown on rating plate. Controls 019430 Gas Control Valve.