Gas salamander

Advertisement

- Australia:
Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
- New Zealand:
Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
- UK Only:
Heat Input (Gross)
Gas Rate
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
NOTE: * Measure burner operating pressure at manifold test point with both burners operating at
full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when
converting between gases, if required. (Refer to 'Gas Conversion' section for details).
31.5 MJ/hr
1.13 - 3.4 kPa
1.0 kPa
31.5 MJ/hr
1.13 - 3.4 kPa
1.0 kPa
Nominal
8.8 kW
Reduced
3.6 kW
Nominal
0.84 m
Reduced
0.34 m
20 mbar
10 mbar
4
31.5 MJ/hr
2.75 - 4.5 kPa
2.55 kPa
½" BSP Male
31.5 MJ/hr
2.75 - 4.5 kPa
2.55 kPa
½" BSP Male
8.8 kW
2.6 kW
3
/hr
0.63 kg/hr
3
/hr
0.19 kg/hr
37 mbar
26 mbar
1
/
" BSP Male
2

Advertisement

loading

This manual is also suitable for:

Sn8200gSn8200gbSnb8200gb