Waldorf SNB8200G Operation Manual page 21

Gas salamander

Advertisement

- Australia:
Main Burner Injectors
Size
Low
Fire
Adjustment
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- New Zealand:
Main Burner Injectors
Size
Low Fire
Adjustment
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- UK Only:
Main Burner Injectors
Size
Low Fire:
Adjustment
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
NOTE: * Measure burner operating pressure at manifold test point with both burners operating at
full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when
converting between gases, if required. (Refer to 'Gas Conversion' section for details).
Ø 1.85mm
Ø 1.00mm
2 turns out (c.c.w.)
1.13 - 3.4 kPa
1.0 kPa
Ø 1.85mm
Ø 1.00mm
2 turns out (c.c.w.)
1.13 - 3.4 kPa
1.0 kPa
Ø 1.85mm
Ø 1.00mm
2 turns out (c.c.w.)
20 mbar
10 mbar
19
Ø 1.15mm
Ø 1.00mm
½ turn out (c.c.w.)
2.75 - 4.5 kPa
2.55 kPa
Ø 1.15mm
Ø 1.00mm
½ turn out (c.c.w.)
2.75 - 4.5 kPa
2.55 kPa
Ø 1.15mm
Ø 1.00mm
½ turn out (c.c.w.)
37 mbar
26 mbar