Download Print this page

All Other Countries - Waldorf SNB8200G Operation Manual

Gas salamander

Advertisement

- All Other Countries:

Main Burner Injectors
Size
Low Fire:
Adjustment
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
Main Burner Injectors
Size
Low Fire:
Adjustment
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
(*) NOTE:
 (*) Measure burner operating pressure at manifold test point with both burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
apart from when converting between gasses, if required.
 (**) TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas
adjustable gas regulator supplied.
 Refer to 'Gas Conversion and Specifications' section of this manual for further details.
Ø 1.85mm
Ø 1.00mm
2 turns out (ccw)
1.13 - 3.40 kPa
1.00 kPa
Adjustable Regulator
(Adjust to the Burner
Operating Pressure)
Ø 1.15mm
Ø 1.00mm
½ turn out (ccw)
2.75 - 4.50 kPa
2.55 kPa
20
Ø 3.50mm
Ø 1.00mm
4 turns out (ccw)
0.76 - 1.50 kPa
0.63 kPa
Ø 1.10mm
Ø 1.00mm
½ turn out (ccw)
2.75 - 4.50 kPa
2.55 kPa

Advertisement

loading

This manual is also suitable for:

Sn8200gSn8200gbSnb8200gb