_3
DI1/DI2
Specify what happens to the DI1/DI2 state, then trigger the event. Options as
below:
-Disabled: disable DI1/DI2 trigger function
-Off->On: When DI1/DI2 status change from OFF to ON, trigger the event
-On->Off: When DI1/DI2 status change from ON to OFF, trigger the event
Triggering Event
Specify the trigger event, total 11 events are support:
-Restart router
-Enable/disable cellular
-Enable/disable WAN
-Enable/disable Internet
-Enable/disable Cloud Service
-DO1 on/off
-DO2 on/off
System Event
Specify what happens in the system, then trigger the DO action.
-Cloud Service Connected/Disconnected
-Internet Connected/Disconnected
-Cellular Abnormally
-WAN Down/Up
DO1/DO2