D X-3 021 Se ri es Ind ustr ia l 4G C lo ud Ro u ter
Slave Starting Address (decimal)
Set up the slave starting address for read/write the registers in a PLC.
Delta PLC: Enter the internal D register number. If you need to read /
write D0, please enter 0 here.
Other: Enter the Hexadecimal or Decimal actual address. For example:
Holding Register: 400100, take 0100 (decimal) that is 64 (hex).
Bit
For X/Y type data of Delta AH/AS series, the address format is x1.x2, then x1
_3
input to slave starting address column, x2 input to this column.
Device Starting Address (decimal)
Set up the device starting address (decimal, input range is from $2048 to
$4095 for word type data, input range is from M0 to M511 for bit type data). $ or
M specifies that the match must start at the beginning of a Device Starting
Address.
Length (1-123)
Set up the number of the continuous address followed by the default mapped
address will be read or write. Input range is from 1 to 64.
Operation
Click the +/- button to add mapping or delete mapping.
Edit
Click an item of register mapping forms that can be edited.
Serial Server-TCP Server
DX router act as a TCP Server, when received the packet from client, parse the packet and transmit to RS-485.
3 - 4 4
Description
Default
N/A
N/A
N/A
N/A
N/A