Delta DX-3021L9 Series User Manual page 91

Industrial 4g / wan cloud router

Advertisement

D X-3 021 Se ri es Ind ustr ia l 4G C lo ud Ro u ter
Remote TSAP
Set up destination TSAP ID when controller is "
S7-1200/1500 ISO TCP
"
Response Timeout
Set up the timeout timer from 50ms to 10000ms. If the set value is out of range,
it will be automatically changed to its maximum or minimum value. The default
is 300ms.
Scan Interval
_3
Set up the time for scan interval, ranging from 50ms to 60000ms.
Add Mappings
Click the button to add a new mapping;
Delete All Mappings
Delete all mappings of this server
Export Configure List
Export the configure list to the file and save to local PC
Import Configure List
Open local file and import the configure list
Read/Write
Set up the access permissions for the mapped register address;
Read-only: The device regular read data from appointed registers in the
slave, but will not update the data to the slave
Write-only: The device updates the data to the slave when the registers
values were changed, but will not read the data from the slave
Read/write: The device regular read data from appointed registers in the
slave, will update the data to the slave when the registers values are
changed.
Data Type
Set up the data type to be collected. Options are:
BIT: bit type
WORD: word type
DWORD(Swap): double word type, and transposition store to DX router's
register in pairs
Address Type
Controller is "S7-200 ISO TCP": Address type options are V/M/Q/I,
combine with data type, it will generate:
- Bit type: VB/MB/QB/IB
- Word type: VW/MW/QW/IW
DWord type:
-
3 - 5 2
Description
S7-200 ISO TCP
"
VD/MD/QD/ID
Default
" or
300
30000
N/A
N/A
N/A
N/A
Read/Write
WORD
DB