Direct Wall Mounting
Offer the plate to the wall in the position the HRT4-B is
to be mounted and mark the fixing positions through
the slots in the wall plate. Drill and plug the wall, then
secure the plate in position. The slots in the wall plate
will compensate for any misalignment of the fixings.
Wiring Box Mounting
The HRT4-B wall plate may be fitted directly on to a
single gang steel flush wiring box complying with
BS 4662:2006 + A1:2009, using two M3.5 screws. The
HRT4-B is suitable for mounting on a flat surface only; it
must not be positioned on an unearthed metal surface.
Electrical Connections
All necessary electrical connections should now be
made. Flush wiring can enter from the rear through the
aperture in the wall plate. For mains voltage
applications a 3 Amp fused spur should be used. The
recommended cable size is 1.0mm2.
12