Component Identification - M-system R7D-TS4/UL Instruction Manual

Thermocouple input module, 4 points (devicenet)

Advertisement

COMPONENT IDENTIFICATION

(A)
(B)
(C)
(D)
1
2
3
X10
X1
MS
NS
NODE ADD.
B.RATE
10 11 12 13
1
2 3 4
5
1
2
(F)
(A) Status Indicator LED
(B) Node Address Setting Rotary SW
(C) Baud Rate Setting Rotary SW
(D) Operating Mode Setting DIP SW (SW1)
(E) PC Configurator Jack
(F) DeviceNet, Power Supply Terminals
(G) Input Terminals
■ STATUS INDICATOR LED
ID
STATE
TO INDICATE
MS
Green
Operating in a normal condition
Blinking Green Standby (needs commissioning)
Red
Critical failure
Blinking Red
Minor failure
OFF
No power supplied
NS
Green
Link on-line and connections in the
established state
Blinking Green Link on-line but no connections in
the established state
Red
Critical link failure
Blinking Red
Minor link failure
OFF
No power supplied
■ NODE ADDRESS
Node Address is selected between 1 and 63 in decimal. The
left switch determines the tenth place digit, while the right
switch does the ones place digit of the address.
Factory setting : 00
Node Address Setting (x1)
Node Address Setting (x10)
■ BAUD RATE
Baud Rate is selected with the rotary switch.
0 : 125 kbps (factory setting)
1 : 250 kbps
2 : 500 kbps
3 thr. 9 : Auto-tracking
Baud Rate Setting
The R7D communicates in the baud rate setting detected at
the startup with the switch set to the positions 0 (125 kbps),
1 (250 kbps) or 2 (500 kbps).
For the settings 3 through 9, it analyzes the PLC' s network
to determine the baud rate on the network.
SEN TRONIC
(E)
4
5
6
7
8
CNFG.
14
15 16 17 18
3
4
5
6
7
8
9
(G)
056 222 38 18
AG
■ OPERATING MODE
(*) Factory setting
• Extension: SW1-1, 1-2
SW1-1
SW1-2 EXTENSION
OFF
OFF
No extension (*)
ON
OFF
Discrete input, 8 or 16 points
OFF
ON
Discrete output, 8 or 16 points
• Conversion Rate: SW1-3
SW1-3
CONVERSION RATE
OFF
250 msec. (*)
ON
500 msec.
• Thermocouple Type: SW1-5, 1-6, 1-7, 1-8
SW1-5
SW1-6
SW1-7
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
ON
ON
■ DeviceNet TERMINAL ASSIGNMENT
1
NO.
ID
1
V+
2
CAN_H
3
Drain
4
CAN_L
5
V–
■ INPUT TERMINAL ASSIGNMENT
10
11
12
13
+IN0
–IN0
+IN1
1
2
3
4
+CJ0
–CJ0
+CJ1
–CJ1
NO.
ID
FUNCTION
1
+CJ0 CJC 0
2
–CJ0 CJC 0
3
+CJ1 CJC 1
4
–CJ1 CJC 1
5
NC
No connection
6
+CJ2 CJC 2
7
–CJ2 CJC 2
8
+CJ3 CJC 3
9
–CJ3 CJC 3
■ EXTENSION MODULE
Combinations with all extension modules are selectable.
mailbox@sentronic.com
www.sentronic.com
R7D-TS4
• Burnout: SW1-4
SW1-4
BURNOUT
OFF
Upscale (*)
ON
Downscale
SW1-8 THERMOCOUPLE TYPE
OFF
K (CA) (*)
OFF
E (CRC)
OFF
J (IC)
OFF
T (CC)
OFF
B (RH)
OFF
R
OFF
S
OFF
C (WRe 5-26)
ON
N
ON
U
ON
L
ON
P (Platinel II)
ON
(PR)
ON
PC Configurator setting
2
3
4
5
FUNCTION, NOTES
Network power supply +
Network data High
Shield
Network data Low
Network power supply –
14
15
16
17
18
–IN1
NC
+IN2
–IN2
+IN3
–IN3
5
6
7
8
9
NC
+CJ2
–CJ2
+CJ3
–CJ3
NO.
ID
FUNCTION
10
+IN0 T/C + 0
11
–IN0 T/C – 0
12
+IN1 T/C + 1
13
–IN1 T/C – 1
14
NC
No connection
15
+IN2 T/C + 2
16
–IN2 T/C – 2
17
+IN3 T/C + 3
18
–IN3 T/C – 3
EM-7802-B Rev.10 P. 2 / 10